Siechem Sietrans GKW US FS 180

  • For Fixed and protected installation inside of rail vehicles.
  • These cables maintain their function over a limited period in the event of a fire and suitable for connecting fixed and moving parts such as emergency lamps, flue gas outlets and switchgear.

  • Conductor : Annealed Tinned Flexible Copper Conductor.
  • Separator : Mica Tape
  • Insulation : Electron Beam Cross Linked Polyolefin Copolymer
  • Colour : As Per Customer Order

  • Nominal voltage U0/U : 0.3/0.5 kV AC
  • Max. permissible operating voltage : (i) U0m : 0.36 kV AC
    (ii) Um : 0.6 kV AC
    (iii) V0 : 0.45 kV DC
    (iv) Vm : 0.9 kV DC
  • Testing voltage : 2kV AC (50Hz / 5min)
  • Max. conductor temperature : +120°C, 20,000 H
  • Short circuit temperature : +280°C
  • Min bending radius : > 3 X Cable OD
  • Fire Safety Performance for Rolling Stock
    i) EN 45545-2 Hazard Level HL1- HL3
    ii) EN 50264-1
  • Vertical flame propagation : (i) EN 60332-1-2 – single cable
  •                                                    (ii) EN 50305 – Bunched cables
  • Smoke density : EN 61034-2
  • Toxicity of gases : EN 50305
  • Halogen free : EN 50267-2-1 & EN 60684-2
  • Corrosivity of gases : EN 50267-2-2
  • Circuit integrity : BS 6387 Category AX IEC 60331-11 : 180 min
  • Material Properties
  • Resistance to ozone : EN 50264-3-1
  • Resistance to oil : EN 50305
  • Resistance to fuel : EN 50305
  • Resistance to acid : EN 50264-3-1
  • Resistance to alkalis : EN 50264-3-1
  • Limiting oxygen index : ISO 4589-2, ASTM D 2863

  • Maintains circuit integrity for 3 hours under fire condition
  • High temperature resistance for use -50°C up to +120°C
  • Oil and fuel resistant
  • Electron beam cross-linked
  • Halogen free
  • Fire resistant

Part Number No. of cores x Cross Section (Nos) x (Sq.mm) Conductor Construction
No.of Strands X Strand dia
(Nos) X (mm)
Nominal
Conductor Diameter
(mm)
Max Conductor
Resistance at 20°C
(Ω/km)
Nominal
Overall Diameter
(mm)
Cable Weight
(Kg/Km) approx.
A54506XX 1 X 0.5 16 X 0.20 0.93 40.1 2.13 ± 0.2 10
A54508XX 1 X 0.75 24 X 0.20 1.14 26.7 2.34 ± 0.2 13
A54510XX 1 x 1.0 32 X 0.20 1.31 20.0 2.61 ± 0.3 16
A54513XX 1 X 1.5 30 X 0.25 1.59 13.7 2.88 ± 0.3 22
A54516XX 1 X 2.5 50 X 0.25 2.05 8.21 3.43 ± 0.3 33

Other length as per Customer order.