More Category
Cables by Segment
Offshore, Marine, Shipboard & Boat Cables
NES 527 – TABLE C6 : Multicore Cables Individually Screened Cores
- Power, Lightning, Control & Communication and Instrumentation circuits in surface ships and submarines.
- Used in fuel and lubrication oils, hydraulic fluids and water surfaces.
- Ship systems & equipments and weapon systems & equipments.
- Conductor : Circular Electroplated, annealed tinned copper wire (Class 2) complying with BS : 6360
- Insulation : Silicone Rubber (Type E)
- Protective Tape : Glass Mica Tape
- Individual Braid : Annealed Tinned Copper (braid 95% Coverage)
- Laying up
- Binder Tape : Polyethylene Teraphthalate
- Outer Sheath : Limited Fire Hazard complying with NES 518 Material – Black.
- Temperature Range : – 300C to +1050C
- Rated Voltage (U°/U) : 440 V
- Test Voltage : 1.5 kV
- Bending Radius(Min) : 6 x Cable Diameter
- Limited Fire Hazard
- Halogen free
Part Number |
Number of Cores and mm2
Per Conductor |
Outer Diameter in
mm approx. |
Copper Index
Kg/Km |
Total Weight
Kg/Km approx. |
521-6918 |
3C x 1.0 |
11.1 |
26 |
182 |
521-6919 |
5C x 1.0 |
13 |
44 |
264 |
521-6920 |
7C x 1.0 |
15.5 |
61 |
335 |
521-6921 |
14C x 1.0 |
19.6 |
122 |
632 |
521-6922 |
18C x 1.0 |
22.2 |
157 |
767 |