Menu

Products

More Category
Cables by Segment

JASO D 608

AEX Cable

  • Low-tension electric wire for Automobiles.
  • Used in Motorcycles and other motor vehicles for starting, charging, lighting, signal and instrument panel circuits.
  • Especially used for circuits requiring heat resistance.

  • Conductor : Soft-annealed electrolytic Copper E-Cu ETP1 according to JIS C 3102 bare conductor  construction according to JASO D 608
  • Insulation : Electron Beam Cross Linked Vinyl.
  • Colour : As per customer order.
  • Single core

  • Temperature Range : – 40°C to +120°C (3000 Hours)
  • Standard : JASO D 608
  • Test Voltage : 1 kV
  • A : Low Voltage wires
  • E : Polyethylene
  • X : Electron Beam Cross Linked
  • Conductor Resistance :IEC 60228/BS 6360

  • Flame retardant.
  • Highly resistant against acids, lyes, Petrol and diesel
  • Flexible conductors with PVC insulation for extra flexibility
  • Excellent flexibility.
  • Heat resistant.

Part
Number
Conductor Construction Insulation
Wall Thickness
Nom.
Cable Max.
Conductor
Resistance
at 200C
Current
Carrying
Capacity
Standard
Length*
Nominal
Cross-
Section
No. of
Strands
Diameter of
Single wire
max.
Conductor
Diameter
Nom.
Overall
Diameter
Weight
Approx.
Nom. Max.
mm2 nos. mm mm mm mm mm kg/km Ω/km Amps mtrs
81306XX* 0.5 7 0.32 1.0 0.50 2.0 2.2 9 32.7 17 1000
81354XX 0.85 11 0.32 1.2 0.50 2.2 2.4 12 20.8 22 1000
81312XX 1.25 16 0.32 1.5 0.60 2.7 2.9 18 14.3 28 1000
81314XX 2 26 0.32 1.9 0.60 3.1 3.4 26 8.81 38 500
81317XX 3 41 0.32 2.4 0.70 3.8 4.1 39 5.59 52 500
81321XX 5 65 0.32 3.0 0.80 4.6 4.9 58 3.52 69 500
81325XX 8 50 0.45 3.7 0.80 5.3 5.6 89 2.32 90 500
Note : XX* : Please add last two digits in the part number as per the colour code given hereunder replacing XX while ordering.
Red – 01 Yellow – 02 Blue – 03 Black – 04 Green – 05 Yellow-Green – 06 Grey – 07 Brown – 08 White – 09 Orange – 10 Violet – 11
Chocolate – 12 Tan – 13 Charcoal – 14 LT Blue – 15 DK Grey – 16 LT Green – 17 DK Green – 18 DK Blue – 19 Purple – 20 Pink – 21

Other length as per Customer order.

Current Carrying capacity given is for the maximum conductor operating temperature of 80°C and ambient air temperature of 40°C.


Enquiry

  • flipbook

Call us now Email us now

Enquiry

Enquiry about this Product

CAPTCHA Image