Single Core Class D 1000V AC EV 150 Cable (Thin wall)

  • Especially used in supporting all line charging euipment.
  • AC & DC Charging (Domestic use & Public charging station).

  • Conductor : Annealed plain copper Conductor according to ISO 19642 (Flexible).
  • Insulation : Electron Beam crossed linked Polyolefin Class D (Thin wall )
  • Insulation Colour : Orange (or) as per customer request

  • Temperature Range : -40°C to 150°C (3000 Hours)
  • Max. Rated Voltage : i) 600V AC (or) 900V DC (0.35Sq.mm)
    ii) 1000V AC (or) 1500V DC (0.5Sq.mm and above)
    (ISO Condcutor size 0.35Sq.mm Shall not be used for 1000V AC (or) 1500V DC Cables)
  • Test Voltage : i) 3kV AC  for 5 mins ( 0.35Sq.mm)
    ii) 10kV AC for 5 mins ( ≥ 0.5Sq.mm)
  • Insulation Faults :  6 kV AC for 900V DC & 8kV AC for 1500V DC Cable
  • Specification : ISO 19642-5, ISO 6722 & Generally as per QC/T 1037-2016**

  • Abrasion Resistant.
  • Thermal Stress-resistant.
  • Halogen-free.
  • Flame resistant.
  • Resistant cold bend and low temperature shock.
  • High charging power upto 500KW.
  • Highly flexible and light weight therefore easy to handle at the charging station.
  • Active liquid cooling as protection against overheating.
  • Fast Charging.
  • Ozone resistant.
  • Soldering Iron Resistant
  • Resistant to liquid chemicals

Part
Number
Conductor Construction Cable Max.
Conductor
Resistance
at 20 degC
Nominal
Cross-
Section
No. of
Strands
Strand Diameter(Max) Insulation
Wall Thickness
(Min)
Overall
Diameter
Min/Max
Weight
Approx
Current Carrying Capacity
mm2 nos. mm mm mm kg/km Amps  Ω/km
 A94105XX* 0.35 45 0.11 0.20 1.20/1.40 5 10 54.4
 A94106XX 0.5 63 0.11 0.22 1.40/1.60 7 18 37.1
  A94108XX 0.75 94 0.11 0.24 1.70/1.90 10 23 24.7
 A94110XX 1 125 0.11 0.24 1.90/2.10 13 28 18.5
 A94112XX 1.25 155 0.11 0.24 2.10/2.30 16 33 14.9
 A94113XX 1.5 182 0.11 0.24 2.20/2.40 18 35 12.7
 A94114XX 2 245 0.11 0.28 2.50/2.80 25 42 9.42
 A94116XX 2.5 140 0.16 0.28 2.70/3.00 29 49 7.60
 A94117XX 3 160 0.16 0.32 3.10/3.40 33 56 6.15
 A94119XX 4 224 0.16 0.32 3.40/3.70 45 66 4.71
 A94121XX 5 250 0.16 0.32 3.90/4.20 51 74 3.94
 A94123XX 6 189 0.21 0.32 4.00/4.30 64 85 3.14
 A94125XX 8 240 0.21 0.32 4.60/5.00 82 103 2.38
 A94127XX 10 320 0.21 0.48 5.30/6.00 111 120 1.82
 A941A11XX 12 380 0.21 0.48 5.80/6.50 131 135 1.52
 A94128XX 16 512 0.21 0.52 6.40/7.20 175 162 1.16
 A94156XX 20 610 0.21 0.52 7.00/7.80 207 188 0.955
 A94130XX 25 790 0.21 0.52 7.90/8.70 264 213 0.743
 A94157XX 30 903 0.21 0.64 8.70/9.60 305 235 0.647
 A94132XX 35 1102 0.21 0.64 9.40/10.40 367 263 0.527
 A94158XX 40 1235 0.21 0.71 10.00/11.10 414 290 0.473
 A94134XX 50 1600 0.21 0.71 11.00/12.20 528 327 0.368
 A94135XX 60 1841 0.21 0.80 12.00/13.30 611 370 0.315
 A94137XX 70 2147 0.21 0.80 13.00/14.40 708 418 0.259
 A94159XX 85 2660 0.21 0.90 14.40/15.80 876 475 0.219
 A94138XX 95 3000 0.21 0.90 15.30/16.70 984 516 0.196
Note : XX* : Please add last two digits in the part number as per the colour code given hereunder replacing XX while ordering.
Red – 01 Yellow – 02 Blue – 03 Black – 04
Green – 05 Yellow-Green – 06 Grey – 07 Brown – 08
White – 09 Orange – 10 Violet – 11 Chocolate – 12
Tan – 13 Charcoal – 14 LT Blue – 15  DK Grey – 16
LT Green – 17 DK Green – 18 DK Blue – 19 Purple – 20
Pink – 21

Other length as per Customer order.

Current Carrying capacity given is for the maximum conductor operating temperature of 150°C and ambient air temperature of 40°C.

**Conductor Construction as per ISO 19642-5. If customer insist construction to be as per ISO 6722 & Generally as per QC/T 1037-2016 or any specific construction, the same can also be supplied.