Part Number |
Conductor Construction | Insulation Wall Thickness Nom |
Sheath Thickness |
Cable | Current Carrying Capacity |
Max. Conductor Resistance at 200C |
Standard Length* |
|||||
---|---|---|---|---|---|---|---|---|---|---|---|---|
Nominal Cross- Section |
No. of Strands |
Diameter of Single wire max. |
Conductor Diameter Nom. |
Overall Diameter Max. |
Weight Approx |
|||||||
mm2 | nos. | mm | mm | mm | mm | mm | kg/km | Amps | Ω/km | mtrs | ||
85419XX* | 4 | 56 | 0.31 | 2.75 | 0.8 | 2.0 | 8.4 | 123 | 61 | 4.71 | 500 | |
85423XX | 6 | 84 | 0.31 | 3.3 | 0.8 | 2.0 | 9.0 | 149 | 77 | 3.1 | 500 | |
85427XX | 10 | 80 | 0.41 | 4.5 | 1.0 | 3.0 | 12.8 | 267 | 263 | 1.82 | 500 | |
85428XX | 16 | 126 | 0.41 | 6.3 | 1.0 | 2.0 | 12.1 | 279 | 139 | 1.16 | 500 | |
85434XX | 50 | 396 | 0.41 | 10.5 | 0.8 | 1.4 | 15.1 | 587 | 337 | 0.368 | 500 | |
85434XX | 50 | 1600 | 0.21 | 10.9 | 0.8 | 1.4 | 15.1 | 592 | 415 | 0.386 | 500 | |
85437XX | 70 | 2200 | 0.21 | 13.3 | 1.0 | 1.6 | 18.3 | 870 | 492 | 0.272 | 500 |
Note : XX* : Please add last two digits in the part number as per the colour code given hereunder replacing XX while ordering. | |||
Red – 01 | Yellow – 02 | Blue – 03 | Black – 04 |
Green – 05 | Yellow-Green – 06 | Grey – 07 | Brown – 08 |
White – 09 | Orange – 10 | Violet – 11 | Chocolate – 12 |
Tan – 13 | Charcoal – 14 | LT Blue – 15 | DK Grey – 16 |
LT Green – 17 | DK Green – 18 | DK Blue – 19 | Purple – 20 |
Pink – 21 |
Other length as per Customer order.
Current Carrying capacity given is for the maximum conductor operating temperature of 80°C and ambient air temperature of 40°C.