- Low-tension electric wire for Automobiles.
- Used in Motorcycles and other motor vehicles for starting, charging, lighting, signal and instrument panel circuits.
Part Number |
Conductor Construction | Insulation Wall Thickness Nom |
Cable | Max. Conductor Resistance at 200C |
Current Carrying Capacity |
Standard Length* |
||||
---|---|---|---|---|---|---|---|---|---|---|
Nominal Cross- Section |
No. of Strands |
Diameter of Single wire max. |
Conductor Diameter Apporx. |
Overall Diameter Max. |
Weight Approx. |
|||||
mm2 | nos. | mm | mm | mm | mm | kg/km | Ω/km | Amps | mtrs | |
83028XX* | 16 | 126 | 0.4 | 5.7 | 1.0 | 8.1 | 171 | 1.21 | 90 | 500 |
83030XX | 25 | 196 | 0.4 | 7.1 | 1.2 | 10.0 | 263 | 0.780 | 118 | 500 |
83032XX | 35 | 276 | 0.4 | 8.5 | 12 | 11.4 | 357 | 0.554 | 146 | 500 |
83034XX | 50 | 396 | 0.4 | 10.3 | 1.4 | 13.7 | 506 | 0.386 | 185 | 500 |
83037XX | 70 | 360 | 0.5 | 12.4 | 1.4 | 15.8 | 703 | 0.272 | 237 | 500 |
83038XX | 95 | 475 | 0.5 | 14.5 | 1.6 | 18.4 | 925 | 0.206 | 291 | 500 |
83041XX | 120 | 608 | 0.5 | 16.0 | 1.6 | 19.9 | 1161 | 0.161 | 342 | 500 |
83042XX | 150 | 756 | 0.5 | 18.0 | 1.8 | 22.4 | 1442 | 0.129 | 402 | 500 |
Note : XX* : Please add last two digits in the part number as per the colour code given hereunder replacing XX while ordering. | |||
Red – 01 | Yellow – 02 | Blue – 03 | Black – 04 |
Green – 05 | Yellow-Green – 06 | Grey – 07 | Brown – 08 |
White – 09 | Orange – 10 | Violet – 11 | Chocolate – 12 |
Tan – 13 | Charcoal – 14 | LT Blue – 15 | DK Grey – 16 |
DK Green – 18 | LT Green – 17 | DK Blue – 19 | Purple – 20 |
Pink – 21 |
Other length as per Customer order.
Current Carrying capacity given is for the maximum conductor operating temperature of 80°C and ambient air temperature of 40°C.