Menu

Products

More Category
Cables by Segment

High Temperature Cables PW 125, Sietherm 125, Sietherm 155 & Fluoro 200

Sietherm 125 Multi Core Cable

  • Internal wiring for high rise buildings, Shopping malls, Public buildings, Airports, School, Hospital
  • Petro chemical plants, Fuel dispensing bunks, Power stations
  • Fire prone areas, Crowded public places, Outdoor traffic systems
  • Sensor leads, Solenoid valves, Signal systems, heaters, Lighting fixtures
  • Plant and Machinery, Motor winding, White goods, Control panels, Switchboards & Industrial applications etc.

  • Conductor: Tinned Flexible Copper Conductor-Class 5 of EN 60228 ( Bare Copper Conductor Optional )
  • Insulation: EBXL 125 Electron Beam Cross Linked Polyolefin Compound
  • Filler : Optional
  • Separator: Polyester Tape
  • Sheath: EBXL 125 Electron Beam Cross Linked Polyolefin Compound
  • Colour: As per customer order

  • Voltage Rating: 600/1000 V
  • Operating Temperature: -40°C to 125°C
  • Short Circuit Temperature: 280°C
  • Test Voltage: 3.5 kV for 5 minutes
  • Ageing Temperature: 150°C for 7 days
  • Minimum Bending radius: Outer diameter ≤ 12 mm: 3 X D                                                                                                                          Outer diameter > 12 mm: 4 X D
  • Flammability: IEC 60332 – 1
  • Smoke Emission: > 70% Absorption
  • Toxicity Index EN 45545-2: < 6
  • Assessment of Halogen pH Conductivity:  > 4.3 < 10 μS/mm
  • Amount of Halogen Acid Gas: HCl & HBr: < 0.5 %                                                                                                                                                                HF:  < 0.1 %

  • Operating temperature -400°C to +1250°C (20,000 hours)
    (Briefly -550°C to +1450°C)
  • Fire retardant and Halogen free
  • Weather resistant
  • High abrasion resistance
  • Ozone & UV resistant
  • Oil & grease resistant
  • High tracking resistance
  • Easily strippable & very flexible
  • Hot pressure resistant
  • Soldering iron resistant
  • High current carrying capacity
  • Short Circuit resistance up to +2800°C for 60 Sec.

Part Number No.of Core X Size No of Strands/ Nom. Strand Dia. Maximum Diameter of Wire in Conductor Nominal Insulation Thickness Nominal Sheath Thickness Overall Cable Diameter (mm) Max.DC Resistance at 20oC ATC Nom Weight
(NosXSq.mm) (Nosxmm) (mm) (mm) (mm) Min Max (Ohm/Km) (Kg/Km)
1810304 4 x 0.25 9/0.12 0.13 0.35 0.8 5.1 5.7 88.5 40
1810604 4 x 0.5 19/0.18 0.19 0.35 0.8 5.8 6.4 40.1 62
1810802 2 x 0.75 24/0.20 0.21 0.5 0.9 6.3 6.9 26.7 63
1810803 3 x 0.75 ;24/0.20 0.21 0.5 0.9 7.0 7.6 26.7 75
1810804 4 x 0.75 24/0.20 0.21 0.5 1.0 7.4 8.0 26.7 90
1810805 5 x 0.75 2/0.20 0.21 0.5 1.1 8.3 8.9 26.7 110
1811002 2 x 1 32/0.20 0.21 0.6 1.0 7.2 7.8 20.0 75
1811003 3 x 1 32/0.20 0.21 0.6 1.0 7.6 8.2 20.0 91
1811302 2 x 1.5 30/0.20 0.26 0.6 0.9 7.5 8.1 13.7 87
1811303 3 x 1.5 30/0.20 0.26 0.6 0.9 8.0 8.6 13.7 110
1811304 4 x 1.5 30/0.20 0.26 0.6 0.9 8.9 9.5 13.7 137
1811305 5 x 1.5 30/0.20 0.26 0.6 1.1 10.0 10.8 13.7 170
1811307 7 x 1.5 30/0.20 0.26 0.6 1.4 11.9 12.7 13.7 242
1811602 2 x 2.5 50/0.25 0.26 0.7 0.9 8.8 9.4 8.21 130
1811603 3 x 2.5 50/0.25 0.26 0.7 1.1 9.7 10.5 8.21 170
1811604 4 x 2.5 50/0.25 0.26 0.7 1.2 10.9 11.7 8.21 210
1811605 5 x 2.5 50/1.25 0.26 0.7 1.3 12.0 12.8 8.21 255
1811904 4 x 4 56/0.30 0.31 0.75 1.3 12.6 13.4 5.09 300
1811905 5 x 4 56/0.30 0.31 0.75 1.4 14.2 15.0 5.09 268
1812704 4 x 10 80/0.40 0.41 1.0 1.8 18.5 19.5 1.95 700
1812705 5 x 10 80/0.40 0.41 1.0 2.0 20.9 21.9 1.95 840

 

Other length as per Customer order.

Current Carrying capacity given is for the maximum conductor operating temperature of 80°C and ambient air temperature of 40°C.


Enquiry

  • flipbook

Call us now Email us now

Enquiry

Enquiry about this Product

CAPTCHA Image