Part Number | Conductor | Insulation | Sheath | Conductor Resistance @ 20°C (Max.) |
Current Carrying Capacity @ 40°C |
||
---|---|---|---|---|---|---|---|
Area (Nom.) | No/dia. of strands | Thickness (Nom.) |
Thickness (Nom.) |
Overall dimensions (Approx.) (W x T) |
|||
Sq.mm | No./mm | mm | mm | mm | Ohms/Km | Amps | |
1391303 | 1.5 | 22/0.3 | 0.6 | 0.9 | 11.0 x 5.0 | 12.1 | 16 |
1391603 | 2.5 | 36/0.3 | 0.7 | 1.0 | 13.0 x 6.0 | 7.41 | 22 |
1391903 | 4.0 | 56/0.3 | 0.8 | 1.0 | 15.3 x 6.7 | 4.95 | 29 |
1392303 | 6.0 | 84/0.3 | 1.0 | 1.15 | 18.6 x 8.0 | 3.30 | 37 |
1392703 | 10 | 80/0.4 | 1.0 | 1.4 | 23.4 x 10.0 | 1.91 | 51 |
1392803 | 16 | 126/0.4 | 1.0 | 1.4 | 28.0 x 11.4 | 1.21 | 68 |
1393003 | 25 | 196/0.4 | 1.2 | 2.0 | 35.4 x 14.8 | 0.780 | 86 |
1393203 | 35 | 276/0.4 | 1.2 | 2.0 | 39.5 x 16.3 | 0.554 | 110 |
1393403 | 50 | 396/0.4 | 1.4 | 2.2 | 45.5 x 18.5 | 0.386 | 145 |
Other length as per Customer order.
Current Carrying capacity given is for the maximum conductor operating temperature of 80°C and ambient air temperature of 40°C.