Menu

Products

More Category
Cables by Segment

Building Wires

House Wiring Cables

  • Single core wires can be used in duct, conduit, or aerial wiring for electric power in houses, buildings, flats, apartments, hospitals, factories and also used with UPS, inverter, battery, control panels etc.,
  • Wiring of panels for use in high ambient temperature

  • Conductor : Soft-annealed plain electrolytic Copper
  • Insulation : PVC, FR PVC, FRLS PVC, HR PVC
  • Colour : As per spec / customer requirement

  • Temperature Range
  •                                i) PVC -FR & FRLS -5° to +70°C
  •                                ii) HFFR -25°C to +90°C
  • Voltage Rating : 1100V
  • Short Circuit Temperature : 160 °C
  • Test Voltage : 3 kV for 5 mins
  • Specification : IS 694

  • Electrolytic grade copper having 100% purity and having 102% conductivity is used to ensure maximum safety
  • Bunching of copper in uniform lay with compact diameter makes stripping and crimping of wires easier & minimizes losses
  • High insulation resistance and dielectric strength
  • Excellent flame retardant properties
  • Enhanced thermal, electrical, mechanical and fire properties

Table 1 – PVC

Part Number Area (Nom.) No. of wires /dia of strands (Max.) Insulation Thickness (Nom.) Overall Diameter(Nom.) Max. Conductor Resistance at 20°C Current Rating
Sq.mm No./mm mm mm Ω/km Amps
10310XX 1 32/0.21 0.6 2.8 19.5 12
10313XX 1.5 30/0.26 0.6 3.1 13.3 16
10316XX 2.5 50/0.26 0.7 3.8 7.98 22
10319XX 4 56/0.31 0.8 4.4 4.95 29
10323XX 6 84/0.31 0.8 5.2 3.30 37
10327XX 10 80/0.41 1.0 6.8 1.91 49

 

Table 2 – FR PVC

Part Number Area (Nom.) No. of wires /dia of strands (Max.) Insulation Thickness (Nom.) Overall Diameter(Nom.) Max. Conductor Resistance at 20°C Current Rating
Sq.mm No./mm mm mm Ω/km Amps
10610XX 1 32/0.21 0.6 2.8 19.5 12
10613XX 1.5 30/0.26 0.6 3.1 13.3 16
10616XX 2.5 50/0.26 0.7 3.8 7.98 22
10619XX 4 56/0.31 0.8 4.4 4.95 29
10623XX 6 84/0.31 0.8 5.2 3.30 37
10627XX 10 80/0.41 1.0 6.8 1.91 49

 

Table 3 – PVC FRLS

Part Number Area (Nom.) No. of wires /dia of strands (Max.) Insulation Thickness (Nom.) Overall Diameter(Nom.) Max. Conductor Resistance at 20°C Current Rating
Sq.mm No./mm mm mm Ω/km Amps
10910XX 1 32/0.21 0.6 2.8 19.5 12
10913XX 1.5 30/0.26 0.6 3.1 13.3 16
10916XX 2.5 50/0.26 0.7 3.8 7.98 22
10919XX 4 56/0.31 0.8 4.4 4.95 29
10923XX 6 84/0.31 0.8 5.2 3.30 37
10927XX 10 80/0.41 1.0 6.8 1.91 49

 

Class 5 Conductor as per IS : 8130 : 2013

XX* – Standard Colours : Red, Yellow, Blue, Black and Green supplied in 90 or 180 metre length. Other sizes, colours and lengths are as per customer order.

 