Part Number |
Conductor Construction | Insulation Wall Thickness Nom |
Cable | Current Carrying Capacity |
Max. Conductor Resistance at 200C |
Standard Length* |
||||
---|---|---|---|---|---|---|---|---|---|---|
Nominal Cross- Section |
No. of Strands |
Diameter of Single wire max. |
Conductor Diameter Nom. |
Overall Diameter Max. |
Weight Approx |
|||||
mm2 | nos. | mm | mm | mm | mm | kg/km | Amps | Ω/km | mtrs | |
83606XX * | 0.5 | 16 | 0.2 | 1.0 | 0.28 | 1.6 | 6 | 13 | 37.1 | 500 |
83610XX | 0.75 | 24 | 0.2 | 1.2 | 0.60 | 2.5 | 33 | 19 | 24.7 | 500 |
83613XX | 1 | 32 | 0.2 | 1.4 | 0.30 | 2.1 | 57 | 21 | 18.5 | 500 |
83616XX | 1.5 | 30 | 0.25 | 1.7 | 0.30 | 2.4 | 111 | 27 | 12.7 | 500 |
83616XX | 2.5 | 50 | 0.25 | 2.1 | 0.70 | 3.7 | 278 | 39 | 7.6 | 500 |
Note : XX* : Please add last two digits in the part number as per the colour code given hereunder replacing XX while ordering. | ||||||||||
Red – 01 | Yellow – 02 | Blue – 03 | Black – 04 | Green – 05 | Yellow-Green – 06 | Grey – 07 | Brown – 08 | White – 09 | Orange – 10 | Violet – 11 |
Chocolate – 12 | Tan – 13 | Charcoal – 14 | LT Blue – 15 | DK Grey – 16 | LT Green – 17 | DK Green – 18 | DK Blue – 19 | Purple – 20 | Pink – 21 |
Other length as per Customer order.
Current Carrying capacity given is for the maximum conductor operating temperature of 80°C and ambient air temperature of 40°C.