Menu

Products

More Category
Cables by Standard

High Temperature Cables PW 125, Sietherm 125, Sietherm 155 & Fluoro 200

Sietherm 125 Single Core Cable

  • Internal wiring for high rise buildings, Shopping malls, Public buildings, Airports, School, Hospital
  • Petro chemical plants, Fuel dispensing bunks, Power stations
  • Fire prone areas, Crowded public places, Outdoor traffic systems
  • Sensor leads, Solenoid valves, Signal systems, heaters, Lighting fixtures
  • Plant and Machinery, Motor winding, White goods, Control panels, Switchboards & Industrial applications etc.

  • Conductor : Tinned Flexible Copper Conductor-Class 5 of EN 60228 ( Bare Copper Conductor Optional )
  • Insulation : EBXL 125 Electron Beam Cross Linked Polyolefin compound
  • Colour : As per customer order

  • Voltage Rating: 600/1000 V
  • Operating Temperature: -40°C to 125°C
  • Short Circuit Temperature: 280°C
  • Test Voltage: 3.5 kV for 5 minutes
  • Ageing Temperature: 150°C for 7 days
  • Minimum Bending radius: Outer diameter ≤ 12 mm: 3 X D                                                                                                                          Outer diameter > 12 mm: 4 X D
  • Flammability: IEC 60332 – 1
  • Smoke Emission: > 70% Absorption
  • Toxicity Index EN 45545-2: < 6
  • Assessment of Halogen pH Conductivity:  > 4.3 < 10 μS/mm
  • Amount of Halogen Acid Gas: HCl & HBr: < 0.5 %                                                                                                                                                                HF:  < 0.1 %

 

  • Operating temperature -400°C to +1250°C (20,000 hours)
    (Briefly -550°C to +1450°C)
  • Fire retardant and Halogen free
  • Weather resistant
  • High abrasion resistance
  • Ozone & UV resistant
  • Oil & grease resistant
  • High tracking resistance
  • Easily strippable & very flexible
  • Hot pressure resistant
  • Soldering iron resistant
  • High current carrying capacity
  • Short Circuit resistance up to +2800°C for 60 Sec.

Part No. Size No.of Strands/ Nom. Stand Dia. Maximun Diameter of Wire in Conductor Nominal Insulation thicknes Overall Cable Diameter Max. DC Resistance at 20oC ATC Nom. Weight Current Rating
Sq.mm2 mm mm mm  Min  Max (Ohm/Km) Kg/Km Amps
18003XX 0.25 19/0.12 0.13 0.4 1.35 1.55 85.9 4.8 9
18070XX 0.34 19/0.15 0.16 0.4 1.5 1.7 52.1 6.1 15
18006XX 0.5 19/0.18 0.19 0.4 1.6 1.8 40.1 7.2 19
18008XX 0.75 24/0.20 0.21 0.5 2.1 2.3 26.7 11.0 24
18010XX 1 32/0.20 0.21 0.6 2.5 2.7 20.0 14.8 29
18013XX 1.5 30/0.25 0.26 0.6 2.6 2.8 13.7 20 36
18016XX 2.5 50/0.25 0.26 0.7 3.4 3.6 8.21 32 49
18019XX 4 56/0.30 0.31 0.7 3.95 4.25 5.09 47 66
18023XX 6 84/0.30 0.31 0.85 4.8 5.1 3.39 70 85
18027XX 10 80/0.40 0.41 0.85 6 6.3 1.95 103 121
18028XX 16 126/0.40 0.41 0.95 7.2  7.5 1.24 158 163
18030XX 25 196/0.40 0.41 1.1 8.7 9.1 0.795 240 219
18032XX 35 276/0.40 0.41 1.2 10.1 10.5 0.565 330 272
18034XX 50 396/0.40 0.41 1.3 11.85 12.35 0.393 468 344
18037XX 70 360/0.50 0.51 1.5 14.15  14.65 0.277 649 439
18038XX 95 475/0.50 0.51 1.6 15.7 16.3 0.210 860 523
18041XX 120 608/0.50 0.51 1.9 18.3 18.9 0.164 1102 621
18042XX 150 756/0.50 0.51 1.9 20.2 20.8 0.132 1355 723
18044XX 185 925/0.50 0.51 2.0 21.9 22.5 1.108 1655 825
18046XX 240 1221/0.50 0.51 2.1 25.1 25.7 0.0817 2120 996
18048XX 300 1525/0.50 0.51 2.15 27.2 27.9 0.0654 2675 1150
18049XX 400 2013/0.50 0.51 2.15 30.7 31.4 0.0495 3430 1473

 

Other length as per Customer order.

Current Carrying capacity given is for the maximum conductor operating temperature of 80°C and ambient air temperature of 40°C.


Enquiry

  • flipbook

Call us now Email us now

Enquiry

Enquiry about this Product

CAPTCHA Image