- Low-tension electric wire for Automobiles.
- Used in Motorcycles and other motor vehicles for starting, charging, lighting, signal and instrument panel circuits.
Part Number |
Conductor Construction | Insulation Wall Thickness Nom |
Cable | Max. Conductor Resistance at 200C |
Current Carrying capacity |
StandardLength* | ||||
---|---|---|---|---|---|---|---|---|---|---|
Nominal Cross- Section |
No. of Strands |
Diameter of Single wire Max. |
Conductor Diameter Max. |
Overall Diameter Max |
Weight Approx |
|||||
mm2 | nos. | mm | mm | mm | mm | kg/km | Ω/km | Amps | mtrs | |
A81105XX** | 0.35 | 7 | 0.27 | 0.90 | 0.30 | 1.40 | 5 | 54.4 | 12 | 2000 |
A81106XX | 0.50 | 19 | 0.19 | 1.10 | 0.30 | 1.60 | 6 | 37.1 | 15 | 2000 |
A81108XX | 0.75 | 19 | 0.24 | 1.30 | 0.30 | 1.90 | 9 | 24.7 | 20 | 2000 |
A81110XX | 1 | 19 | 0.27 | 1.50 | 0.30 | 2.10 | 11 | 18.5 | 24 | 2000 |
A81113XX | 1.5 | 19 | 0.33 | 1.80 | 0.30 | 2.40 | 17 | 12.7 | 30 | 2000 |
A81114XX | 2 | 19 | 0.38 | 2.00 | 0.35 | 2.80 | 23 | 9.42 | 37 | 2000 |
A81116XX | 2.5 | 37 | 0.28 | 2.20 | 0.35 | 3.00 | 26 | 7.60 | 42 | 2000 |
A81117XX | 3 | 37 | 0.34 | 2.40 | 0.40 | 3.40 | 34 | 6.15 | 49 | 1000 |
A81119XX | 4 | 37 | 0.38 | 2.80 | 0.40 | 3.70 | 42 | 4.71 | 58 | 1000 |
A81121XX | 5 | 37 | 0.43 | 3.10 | 0.40 | 4.20 | 53 | 3.94 | 66 | 1000 |
A81123XX | 6 | 37 | 0.45 | 3.40 | 0.40 | 4.30 | 60 | 3.14 | 75 | 1000 |
A81127XX | 10 | 63 | 0.46 | 4.50 | 0.60 | 6.00 | 106 | 1.82 | 108 | 1000 |
A81128XX | 16 | 105 | 0.46 | 6.30 | 0.65 | 7.90 | 177 | 1.16 | 147 | 1000 |
A81130XX | 25 | 154 | 0.46 | 7.80 | 0.65 | 9.40 | 249 | 0.743 | 193 | 1000 |
Note : XX* : Please add last two digits in the part number as per the colour code given hereunder replacing XX while ordering. | |||
Red – 01 | Yellow – 02 | Blue – 03 | Black – 04 |
Green – 05 | Yellow-Green – 06 | Grey – 07 | Brown – 08 |
White – 09 | Orange – 10 | Violet – 11 | Chocolate – 12 |
Tan – 13 | Charcoal – 14 | LT Blue – 15 | DK Grey – 16 |
LT Green – 17 | DK Green – 18 | DK Blue – 19 | Purple – 20 |
Pink – 21 |
Other length as per Customer order.
Current Carrying capacity given is for the maximum conductor operating temperature of 80°C and ambient air temperature of 40°C.