Wind Energy

Wires & Cables Siechem Flexible Polyolefin Control Cable Application Product Construction Technical Data Features Part Number 2 Number of Cores and mm Per Conductor Outer Diameter in mm approx. Weight Kg/Km approx. Copper Index Kg/Km approx. 1 X 0.25 2 X 0.25 3 G 0.25 4 G 0.25 5 G 0.25 6 G 0.25 7 G 0.25 8 G 0.25 10 G 0.25 12 G 0.25 14 G 0.25 16 G 0.25 19 G 0.25 21 G 0.25 1 X 0.5 2 G 0.5 3 G 0.5 4 G 0.5 5 G 0.5 6 G 0.5 7 G 0.5 8 G 0.5 10 G 0.5 12 G 0.5 14 G 0.5 16 G 0.5 19 G 0.5 21 G 0.5 24 G 0.5 25 G 0.5 27 G 0.5 30 G 0.5 33 G 0.5 37 G 0.5 1 X 0.75 2 X 0.75 3 G 0.75 4 G 0.75 5 G 0.75 3.1 4.9 5.2 5.8 6.1 6.8 7.2 7.6 8.4 8.4 8.9 9.2 10.4 10.8 3.5 5.6 6.0 6.5 7.3 7.7 8.4 9.3 10.3 10.3 10.8 11.6 12.7 13.3 14.3 14.3 14.3 14.9 15.7 16.8 3.8 6.3 6.7 7.3 8.2 2.4 4.8 7.2 9.6 12.0 14.4 16.8 19.2 24.0 28.8 33.6 38.4 45.6 50.4 4.8 9.6 14.4 19.2 24.0 28.8 33.6 38.4 48.0 57.6 67.2 76.8 91.2 100.8 115.2 120.0 129.0 144.0 158.4 177.6 7.2 14.4 21.6 28.8 36.0 11 29 34 42 47 58 64 71 84 90 102 114 132 145 16 39.6 48.1 51 64 74 88 102 123 135 153 176 213 234 263 269 280 311 343 392 20 40 53 69 86 74 All information given are in good faith.Siechem's liability is only to replace the defective portion of cables provided the same is mutually established as manufacturing defects within the guarantee period as agreed in writing and Siechem shall not be liable for any compensation or damages. Siechem reserves the right to revise any of the above specifications without prior intimation. Subject to Chennai Jurisdiction. Multi Core Flexible Plain Copper Conductor, Polyolefin Copolymer Insulated, ATC (-SB) Braided & Polyolefin Copolymer Sheathed 0.6/1kV Control Cable 3780001 3780002 3780003 3780004 3780005 3780006 3780007 3780008 3780010 3780012 3780014 3780016 3780019 3780021 3780601 3780602 3780603 3780604 3780605 3780606 3780607 3780608 3780610 3780612 3780614 3780616 3780619 3780621 3780624 3780625 3780627 3780630 3780633 3780637 3780801 3780802 3780803 3780804 3780805 ü Used for measuring and controlling purposes in wind turbines. ü Excellent Flame Retardant. ü Halogen free ü Non corrosive 0 ü Cold Resistant at 50 C ü Oil, Abrasion and Weathering Resistant. ü Conductor ü Insulation ü Shield ü Outersheath ü Temperature Range: 0 0 Fixed : -55 C to +125 C 0 0 Flexing : -35 C to +120 C 2 ü Rated Voltage : 450/750 V (0.75 mm ) 2 600/1000 V (1.0 mm ) ü Test Voltage : 4.0 kV ü Min. Bending Radius : Fixed : 4 x Cable dia Flexing : 12 x Cable dia : Bare Copper, Fine wire conductors according to IEC 60228, Class 5 : Polyolefin copolymer : Screen braid of tinned copper wires (-SB) : Polyolefin copolymer AS 9100 ISO 45001 ISO 9001 ISO 14001

RkJQdWJsaXNoZXIy NDgyMjA=