Wind Energy

Wires & Cables Siechem Flexible Halogen Free TPE Control Cable Application Product Construction Technical Data Features Part Number 2 Number of Cores and mm Per Conductor Outer Diameter in mm approx. Weight Kg/Km approx. Copper Index Kg/Km approx. 2 X 0.5 3 G 0.5 4 G 0.5 5 G 0.5 7 G 0.5 12 G 0.5 18 G 0.5 25 G 0.5 34 G 0.5 41 G 0.5 50 G 0.5 61 G 0.5 2 G 0.75 3 G 0.75 4 G 0.75 5 G 0.75 7 G 0.75 12 G 0.75 18 G 0.75 25 G 0.75 34 G 0.75 41 G 0.75 50 G 0.75 61 G 0.75 2 X 1 3 G 1 4 G 1 5 G 1 7 G 1 12 G 1 18 G 1 25 G 1 34 G 1 41 G 1 50 G 1 61 G 1 2 X 1.5 3 G 1.5 4 G 1.5 6.0 6.4 7.0 7.6 9.1 11.4 13.2 16.3 18.0 19.8 21.6 24.1 6.3 6.8 7.4 8.2 9.8 11.9 14.2 17.4 19.4 21.2 23.3 25.6 6.6 7.1 7.8 8.7 10.3 12.8 15.0 18.3 20.6 22.7 24.7 27.1 7.7 8.3 9.0 9.6 14.0 19.0 24.0 34.0 58.0 86.0 120.0 163.0 197.0 240.0 293.0 14.4 22.0 29.0 36.0 50.0 86.0 130.0 180.0 245.0 296.0 360.0 439.0 19.2 29.0 39.0 48.0 67.0 115.0 173.0 240.0 326.0 394.0 480.0 586.0 28.8 43.0 58.0 52 63 69 87 119 198 266 380 508 594 715 840 66 76 85 113 144 245 327 466 626 747 896 1,070 70 88 99 132 170 285 405 570 742 885 1,071 1,265 91 110 141 71 All information given are in good faith.Siechem's liability is only to replace the defective portion of cables provided the same is mutually established as manufacturing defects within the guarantee period as agreed in writing and Siechem shall not be liable for any compensation or damages. Siechem reserves the right to revise any of the above specifications without prior intimation. Subject to Chennai Jurisdiction. Multi Core Flexible Plain Copper Conductor Halogen Free TPE Insulated, ATC (-SB) Braided & Halogen Free PUR Sheathed 600V Control Cable 3770602 3770603 3770604 3770605 3770607 3770612 3770618 3770625 3770634 3770641 3770650 3770661 3770802 3770803 3770804 3770805 3770807 3770812 3770818 3770825 3770834 3770841 3770850 3770861 3771002 3771003 3771004 3771005 3771007 3771012 3771018 3771025 3771034 3771041 3771050 3771061 3771302 3771303 3771304 ü PVC Self Extinguishing ü Excellent Flame Retardant. ü Oil Resistant. ü Conductor ü Insulation ü Shield ü Outersheath : Flexible Bare Copper Conductor according to IEC 60228, Class 6 : Heat Resistant Special PVC : ATC (-SB) : Heat Resistant Special PVC ü Temperature Range: 0 0 Fixed : -40 C to +90 C 0 0 Flexing : -5 C to +90 C (UL /CSA) ü Rated Voltage : 600 V (UL /CSA) ü Test Voltage : 3.0 kV ü Breakdown Voltage : Min. 6.0 kV ü Min. Bending Radius : Fixed : 4 x Cable dia Flexing : 7.5 x Cable dia ü Used as wiring cables for control in wind turbines. AS 9100 ISO 45001 ISO 9001 ISO 14001

RkJQdWJsaXNoZXIy NDgyMjA=