Wind Energy
32 www.siechem.com All information given are in good faith.Siechem's liability is only to replace the defective portion of cables provided the same is mutually established as manufacturing defects within the guarantee period as agreed in writing and Siechem shall not be liable for any compensation or damages. Siechem reserves the right to revise any of the above specifications without prior intimation. Subject to Chennai Jurisdiction. Catalogue No 362 Wires & Cables Part Number 2 Number of Cores and mm Per Conductor Outer Diameter in mm approx. Weight Kg/Km approx. 3 X 1.5 re 4 X 1.5 re 5 X 1.5 re 7 X 1.5 re 10 X 1.5 re 12 X 1.5 re 14 X 1.5 re 16 X 1.5 re 19 X 1.5 re 24 X 1.5 re 30 X 1.5 re 3 X 2.5 re 4 X 2.5 re 5 X 2.5 re 7 X 2.5 re 10 X 2.5 re 12 X 2.5 re 14 X 2.5 re 19 X 2.5 re 24 X 2.5 re 30 X 2.5 re 3 X 4 re 4 X 4 re 5 X 4 re 3 X 6 re 4 X 6 re 5 X 6 re 3 X 10 re 4 X 10 re 5 X 10 re 3 X 16 re 4 X 16 re 5 X 16 re 12 13 14 15 18 19 20 21 22 24 26 13 14 15 16 20 20 21 23 26 28 15 16 17 16 17 19 18 19 21 20 22 23 223 256 293 360 520 560 620 680 760 900 1,100 272 316 323 450 630 680 790 990 1,300 1,400 373 439 510 466 547 640 629 743 899 850 1,039 1,240 3621303 3621304 3621305 3621307 3621310 3621312 3621314 3621316 3621319 3621324 3621330 3621603 3621604 3621605 3621607 3621610 3621612 3621614 3621619 3621624 3621630 3623803 3623804 3623805 3622303 3622304 3622305 3622703 3622704 3622705 3622803 3622804 3622805 Multi Core Stranded Copper Conductor PVC Insulated & Sheathed 600/1000V (UA) Power Cable conforming to IEC 60228 Application Product Construction Technical Data Features ü Used in Power lines of fixed routing in wind tower installation. ü Electron Beam Cross Linked insulation. ü Excellent Flame Retardant. ü Highly Resistive to Oil and Ozone. ü UV Resistant. ü Highly short circuit rated and earth fault resistance cable. ü Conductor ü Insulation ü Filling ü Outersheath : Finely stranded, according to IEC 60228 : PVC : Filling compound over the core assembly : PVC ü Temperature Range: 0 0 Fixed : - 40 C to +70 C 0 0 Flexing : - 5 C to +50 C ü Test Voltage : 4.0kV ü Rated Voltage (U /U) : 0.6/1.0kV 0 ü Min. Bending Radius : Singlecore : 15 x Cable dia Multicore : 12 x Cable dia ü re : round conductor, singlewire rm : round conductor, multiwire sm : sectional conductor. Siechem PVC (UA) Copper Power Cable Copper Index Kg/Km approx. 38 51 63 89 127 152 177 203 241 304 380 63 84 106 148 211 253 296 401 507 633 101 135 169 152 203 253 253 338 422 405 541 676 AS 9100 ISO 45001 ISO 9001 ISO 14001
Made with FlippingBook
RkJQdWJsaXNoZXIy NDgyMjA=