Wind Energy
20 All information given are in good faith.Siechem's liability is only to replace the defective portion of cables provided the same is mutually established as manufacturing defects within the guarantee period as agreed in writing and Siechem shall not be liable for any compensation or damages. Siechem reserves the right to revise any of the above specifications without prior intimation. Subject to Chennai Jurisdiction. Wires & Cables Part Number 2 Number of Cores and mm Per Conductor Outer Diameter in mm approx. Copper Index Kg/Km Total Weight Kg/Km approx. Application Product Construction Technical Data Permanent installations in marine crafts Installations in open decks as Control and Power cables Features Temperature Range Rated Voltage (U /U) o Bending Radius(Min) Short-circuit temp. (max.) Conductor Insulation Foil Screen Screen Separator Outer Sheath : Electrolytic, stranded, annealed copper wire. IEC 60228 Class 2 (Class 5 / tinned on request) : HEPR (Halogen free) : Al-Mylar Tape : Electrolytic Copper Braided Screen : Polyester Tape : Halogen free, flame retardant, thermoset, polyolefin based jacket compound (Black) 0 0 : - 40 C to +120 C : 0.6/1kV : 5 x Cable Diameter 0 : 280 C 1 x 4 1 x 6 1 x 10 1 x 16 1 x 25 1 x 35 1 x 50 1 x 70 1 x 95 1 x 120 1 x 150 1 x 185 1 x 240 1 x 300 9.0 10.0 11.0 12.0 14.0 15.5 17.5 19.5 22.0 23.5 26.0 28.5 31.5 34.4 2 x 1.5 2 x 2.5 2 x 4 2 x 6 2 x 10 2 x 16 2 x 25 15.0 16.0 17.0 18.5 20.0 22.5 26.5 3 x 1.5 3 x 2.5 3 x 4 3 x 6 3 x 10 3 x 16 3 x 25 3 x 35 3 x 50 3 x 70 15.5 16.5 18.0 19.0 21.5 24.0 28.0 31.0 35.0 39.0 76 99 144 209 306 411 567 774 1029 1311 1610 1963 2501 3340 200 230 290 370 510 620 790 1040 1360 1610 1910 2360 3010 3660 100 127 165 212 302 466 665 370 430 490 600 750 970 1330 Siechem MGSGO 120 156 210 277 412 631 919 1228 1698 2408 410 470 550 670 870 1140 1640 2050 2640 3510 Flame retardant : IEC - 60332-3 (Cat A) Tests & Materials : IEC - 60092/350-351-359 Halogen free : IEC 60754 / 1-2 Electron Beam Cross Linked Smoke Density : IEC 60134 / 1-2 (DIN EN 50147-1) Oil resistant * Multi Core Stranded Copper Conductor,HEPR (Halogen free) Insulated, Al- Mylar Tape, Electrolytic Copper Braided Screen, Polyester Tape & Polyolefin Sheathed 600/1000V (UA) Marine Cable conforming to IEC 60228 30319XX 30323XX 30327XX 30328XX 30330XX 30332XX 30334XX 30337XX 30338XX 30341XX 30342XX 30344XX 30346XX 30348XX 3031302 3031602 3031902 3032302 3032702 3032802 3032802 3031302 3031602 3031902 3032302 3032702 3032802 3033002 3033203 3033403 3033703 AS 9100 ISO 45001 ISO 9001 ISO 14001
Made with FlippingBook
RkJQdWJsaXNoZXIy NDgyMjA=