Wind Energy

Siechem HO7RN - F Control Cable Wires & Cables Technical Data Application Features ü Used in dry and damp interiors. ü Also in Outdoor Use. ü Used in Agricultural Machinery. ü Heavy Duty Cable. ü Excellent Flame retardant, Ozone resistant and oil resistant OuterSheath. 0 0 ü Temperature Range : - 25 C to +60 C ü Voltage for Testing : 2.5 kV ü Protective Conductor(PC) : G-With green/yellow PC X-Without PC ü Bending Radius(Minimum): Flexing : 6 x Cable Diameter ü Rated Voltage : (U /U) 45/750 V 0 In Protected &Fixed Installations : 600/1000 V ü Specific Insulation Resistance : 1 G Ohm x cm. ü As per VDE 0282 Product Construction ü Conductor : Fine Strands of Copper. ü Insulation : Rubber Compound. ü Outer Sheath : Polychloroprene Rubber Compound. ü Colored Cores. Part Number 2 Number of Cores and mm Per Conductor Outer Diameter in mm approx. Copper Index Kg/Km Weight Kg/Km approx. 3G1 2Cx1.5 3G1.5 4G1.5 5G1.5 7G1.5 12G1.5 19G1.5 24G1.5 25G1.5 2Cx2.5 3G2.5 4G2.5 5G2.5 7G2.5 12G2.5 19G2.5 24G2.5 25G2.5 2Cx4 3G4 4G4 5G4 7G4 3G6 4G6 5G6 3G10 4G10 5G10 3G16 4G16 5G16 4G25 5G25 4G35 5G35 4G50 5G50 4G70 4G95 4G120 4G150 4G185 4G240 7.5 8.0 8.5 9.4 10.4 11.4 14.8 17.7 21.0 21.0 8.9 9.5 10.5 11.6 12.8 16.7 20.0 23.8 23.8 10.6 11.3 12.5 13.8 15.2 13.4 14.8 16.4 15.9 17.5 19.3 18.2 20.1 22.2 25.2 27.8 28.2 31.0 33.8 37.2 38.1 43.4 47.4 52.8 57.9 65.4 27.2 26.5 39.8 53.0 66.3 95.6 163.8 259.4 327.6 341.3 44.5 66.7 88.9 111.2 160.2 274.7 434.9 549.4 572.3 71.6 107.4 143.2 179.0 258.0 161.3 215.0 268.8 274.2 365.6 457.0 439.1 585.5 731.9 910.3 1137.8 1281.1 1601.4 1836.0 2295.0 2611.2 3449.6 4410.5 5483.5 6707.5 8853.6 87 95 116 145 177 226 330 507 637 661 128 158 199 244 316 470 726 913 948 188 234 295 363 473 337 425 522 509 645 792 732 933 1151 1458 1794 1932 2383 2776 3420 3745 4912 6091 7560 9174 11960 6441003G 6441302 6441303G 6441304G 6441305G 6441307G 6441312G 6441319G 6441324G 6441325G 6441602 6441603G 6441604G 6441605G 6441607G 6441615G 6441619G 6441624G 6441625G 6441902 6441903G 6441904G 6441905G 6441907G 6442303G 6442304G 6442305G 6442703G 6442704G 6442705G 6442803G 6442804G 6442805G 6443004G 6443005G 6443204G 6443205G 6443404G 6443405G 6443704G 6443804G 6444104G 6444204G 6444404G 6444604G Multi Core Flexible Copper Conductor Rubber Insulated & Polychloroprene Rubber Sheathed 450/750V (UA) Control Cable 13 All information given are in good faith.Siechem's liability is only to replace the defective portion of cables provided the same is mutually established as manufacturing defects within the guarantee period as agreed in writing and Siechem shall not be liable for any compensation or damages. Siechem reserves the right to revise any of the above specifications without prior intimation. Subject to Chennai Jurisdiction. AS 9100 ISO 45001 ISO 9001 ISO 14001

RkJQdWJsaXNoZXIy NDgyMjA=