Solar Booklets
www.siechem.com 39 Single Core Aluminium Conductor EBXL-XLPE 120°C Insulated, HR PVC Sheathed, (UA) UV Resistant Power Cable Construction: Operating Temperature : -15°C to +120°C High Insulation resistance at elevated temperature Short Circuit Temperature : 250°C Bending radius (min) : 12 x Cable dia Test Voltage : 3 kV for 5 mins. Technical Data Conductor Insulation Jacket : : : Aluminium conductor complying with IS : 8130 - 1984 PVC ST 2 & UV Resistant complying with IS : 5831 - 1984. (Colour Black) Optional : 105°C HR PVC (UV) Electron Beam Cross Linked Polyethylene 120°C Electron Beam Cross Linked. Does not melt or drip Enhanced Mechanical, Electrical, Thermal & Weathering properties. Flame retardant Excellent UV and Ozone resistant. Specially designed for PV Power cable segment. Features Applications PV Power cables Transmission and distribution of Power Industrial units Commercial and residential places Indoor and outdoor uses Cable ducts, cable trays and conduits Direct burial. Rating factors for variation in ambient air temperature : 0 Temperature - C Rating Factors Conductor 0 Temp. 120 C 20 25 30 35 40 45 50 55 60 65 70 75 80 1.12 1.09 1.06 1.03 1.00 0.97 0.94 0.91 0.88 0.83 0.79 0.75 0.71 Catalogue No 652S/653S Wires & Cables Specification : IS : 7098 (P-1) / 1988 (with enhanced operating temperature) Siechem offers 120 ° C EBXL XLPE as against 90°C offered by rest of the competition Note : Please replace XX in the part number as per the colour code given hereunder. Red - 01 Yellow - 02 Blue - 03 Black - 04 Green - 05 Yellow-Green - 06 Grey - 07 Siechem EBXLXLPE 120°CAluminium (UA) Power Cable 0 0 Current ratings given in this leaflet are calculated at an ambient air temperature 40 C and ground temperature 30 C 0.38 0.57 0.94 1.5 2.4 3.3 4.7 6.6 9.0 11.3 14.2 17.5 22.6 28.3 37.7 47.2 59.4 Short Circuit Rating for 1 sec Current Rating For EBXL - XLPE Cables (120°C) Max. D.C Resistance at 20 deg.C Approx. Capacitance per phase Conductor Area Cond. Min. No. of Wires Thickness of EBXL XLPE Insulation (Nom.) Thickness of Outer Sheath (Nom.) Approx. Overall Diameter Approx. Net Wt. of Cable Direct in Ground In Duct In Air Sq.mm Nos mm Ohm /Km KA µF/Km Amps Amps Amps mm Kg/Km mm Part Number 652S19XX04 652S23XX04 652S27XX04 653S28XX04 653S30XX04 653S32XX04 653S34XX04 653S37XX04 653S38XX04 653S41XX04 653S42XX04 653S44XX04 653S46XX04 653S48XX04 653S49XX04 653S50XX04 653S51XX04 4 6 10 16 25 35 50 70 95 120 150 185 240 300 400 500 630 0.7 0.7 0.7 0.7 0.9 0.9 1.0 1.1 1.1 1.2 1.4 1.6 1.7 1.8 2.0 2.2 2.4 1.8 1.8 1.8 1.8 1.8 1.8 1.8 1.8 1.8 1.8 2.0 2.0 2.0 2.0 2.2 2.2 2.2 7.5 8.0 9.0 10.0 11.5 12.5 13.5 15.5 17.0 19.0 21.0 23.0 26.0 28.0 33.0 36.0 40.0 0.29 0.34 0.43 0.51 0.487 0.545 0.586 0.643 0.731 0.755 0.724 0.705 0.764 0.794 0.823 0.835 0.859 7.41 4.61 3.08 1.91 1.20 0.868 0.641 0.443 0.320 0.253 0.206 0.164 0.125 0.100 0.0778 0.0605 0.0469 65 80 90 125 160 190 250 325 415 520 625 750 960 1120 1450 1760 2210 1 1 1 6 6 6 6 12 15 15 15 30 30 30 53 53 53 48 62 74 97 126 152 180 224 267 311 349 398 463 534 611 709 819 57 71 87 112 149 176 212 258 310 351 394 453 522 597 661 754 858 55 68 83 109 143 178 217 281 342 399 460 529 627 725 875 1013 1178 TUV AS 9100 ISO 45001 ISO 9001 ISO 14001
Made with FlippingBook
RkJQdWJsaXNoZXIy NDgyMjA=