ü Rated Voltage : 1.0/1.0kV AC, 1.5kV DC ü Max. Permitted Operating Voltage : 1.8kV DC ü Temperature Range : - 40 ºC to +120 ºC ü Max. Continuous Working Temp : 120º C (20,000h) ü Max. Conductor Temperature at Rated Current : 90ºC ü Permitted Short Circuit Temperature : 250º C for 5 Sec ü AC Test Voltage : 6.5 kV, 50Hz for 5 minutes ü Specification : Generally as per EN 50618 ü Min. Bending Radius : 5 X Cable OD ü Conductor Annealed Tinned Flexible Copper Conductor (APC Optional) ü Insulation EBXL - XLPO (Low Smoke Halogen free) ü Core Colour Red ü Inner Sheath Nylon ü Outer Sheath EBXL - XLPO with Anti-Rodent & Anti-Termite Properties ü Sheath Colour Black with Red stripe Application Product Construction Technical Data Features 1 X 1.5 1 X 2.5 1 X 4 1 X 6 1 X 10 1 X 16 1 X 25 1 X 35 1 X 50 1 X 70 1 X 95 1 X 120 1 X 150 1 X 185 1 X 240 A518130139 A518160139 A518190139 A518230139 A518270139 A518280139 A518300139 A518320139 A518340139 A518370139 A518380139 A518410139 A518420139 A518440139 A518460139 0.26 0.26 0.31 0.31 0.41 0.41 0.41 0.41 0.41 0.51 0.51 0.51 0.51 0.51 0.51 0.7 0.7 0.7 0.7 0.7 0.7 0.9 0.9 1.0 1.1 1.1 1.2 1.4 1.6 1.7 www.siechem.com Strand Dia. (Max.) Thickness of Insulation Thickness of Outer Sheath No. of Core x Nominal Cross Sectional Area Part Number mm mm (Nom) (Nom) 46 58 74 94 135 200 305 405 555 740 965 1190 1480 1850 2350 24 33 44 57 79 107 142 176 221 278 333 390 453 515 620 13.7 8.21 5.09 3.39 1.95 1.24 0.795 0.565 0.393 0.277 0.210 0.164 0.132 0.108 0.0817 Overall Diameter of Cable (Nom.) Approx Cable Weight DC Conductor Resistance at 20°C (Max) 0.8 0.8 0.8 0.8 0.8 0.9 1.0 1.1 1.2 1.2 1.3 1.3 1.4 1.6 1.7 5.5 5.9 6.5 7.0 8.0 9.3 11.3 12.6 14.8 16.8 18.8 20.3 22.7 25.2 27.8 mm mm kg/km No. X Sq.mm Siechem Annealed Tinned Flexible Copper Conductor, EBXL XLPO Insulated, Nylon Inner Sheathed and EBXL XLPO Outer Sheathed Single Core Solar PV Cable (Anti-Rodent & Anti-Termite Properties) Ω /km : : : : : ü Used in Photovoltaic Power Supply systems Indoor & Outdoors ü Applicable for Installation in Cable trays, Conduits and in wall as well as for direct burial ü Resistance against UV, Water, Ozone, Fluids, Oil, Salt & General Weathering ü Electron Beam Cross Linked Halogen free, Flame Retardant, Low Smoke Emission Fire Retardant to meet IEC 607541-1/ EN 50268-2 RoHS Compliant as per EU norms. Voltage Resistance Test complies as per EN 50395 ü Resistant to Anti-Rodent and Anti-Termite attacks ü Current Rating for Two Loaded Cables Touching on Surfaces Amps Siechem 1C X 4 Sqmm Single Core Nylon Inner Sheathed Solar Cable Wires & Cables 19 TUV AS 9100 ISO 45001 ISO 9001 ISO 14001 Catalogue No A518
Made with FlippingBook
RkJQdWJsaXNoZXIy NDgyMjA=