Solar Booklets

www.siechem.com 17 Singlecore GI Wire Braided Anti-Rodent Solar DC Cables Nominal Insulation Thickness Max. DC Conductor Resistance at 20°C Cable Diameter (Nom) Cable Weight (Nom) Current Rating for Two Loaded Cables Touching on Surfaces Cross Section Area Part Number Sq.mm mm mm Kg/Km Amps 1.5 2.5 4 6 10 16 25 35 50 70 95 120 150 185 240 *Note : Insulations colour (XX) - Please add two digits in the part number as per the colour code given hereunder replacing XX while ordering Red - 01, Black - 04, White - 09 Sheath Colour (YY) please add two digits in the part number as per the colour code given hereunder replacing YY while ordering Red - 01, Blue - 03, Black - 04, Brown - 08, Grey - 07, Black / Red - 39* 0.7 0.7 0.7 0.7 0.7 0.7 0.9 0.9 1.0 1.1 1.1 1.2 1.4 1.6 1.7 13.7 8.21 5.09 3.39 1.95 1.24 0.795 0.565 0.393 0.277 0.210 0.164 0.132 0.108 0.0817 9.5 ± 0.9 10.0 ± 1.0 11.0 ± 1.1 11.5 ± 1.2 12.5 ± 1.3 14.0 ± 1.4 15.5 ± 1.6 16.5 ± 1.7 18.5 ± 1.9 20.5 ± 2.1 22.0 ± 2.2 24.0 ± 2.4 26.0 ± 2.6 29.0 ± 2.9 31.5 ± 3.2 145 160 195 225 280 360 485 600 785 995 1240 1500 1830 2235 2770 24 33 44 57 79 107 142 176 221 278 333 390 453 515 620 Ω /km B56713XXYY B56716XXYY B56719XXYY B56723XXYY B56727XXYY B56728XXYY B56730XXYY B56732XXYY B56734XXYY B56737XXYY B56738XXYY B56741XXYY B56742XXYY B56744XXYY B56746XXYY Wires & Cables Single Core Anti-Rodent GI Wire Braided Flexible Copper Conductor Electron Beam Irradiated Solar DC Cable Generally as per EN 50618 Construction Features Conductor Insulation Inner Sheath Outer Sheath Braiding : : : : : Annealed Tinned Copper (APC Optional) according to IEC 60228, Class 5 or as per customer order EBXL - XLPO 120ºC (UV Resistant) EBXL - XLPO 120º C Highly Weather & UV Resistant (Colour Black, Blue, Red, Brown, Grey, Black with Red stripe) EBXL - XLPO 120°C (Colour White, Red & Black) Other colours as per customer order Single Core Siechem Solar Cable Range Type of Solar cables Siechem Single & Multicore Solar Cables meets specification EN 50618 Siechem Single & Multicore Solar Cables meets specification UL 4703 Siechem Single & Multicore Solar Cables to meet both EN & UL specification 1.5 to 240sq.mm or its equivalent size in AWG : Anti-Termite and Anti-Rodent Properties Resistance against UV, Water, Ozone, Fluids, Oil, Salt & General Weathering. Electron Beam Cross Linked Halogen Free, Flame Retardant, Low Smoke Emission Fire retardant to meet IEC 607541-1/EN 50268-2 RoHS compliant as per EU norms Max.Temp. at Conductor Test Voltage Voltage Resistance Test Rated Voltage Short Circuit Temp : 6500V AC for 5 minutes : : +280°C : EN 50395 120°C (20,000h) : Nominal Inner Sheath Thickness Braiding Wire Dia (Nom) Nominal Outer Sheath Thickness 0.8 0.8 0.8 0.8 0.8 0.9 1.0 1.1 1.2 1.2 1.3 1.3 1.4 1.6 1.7 0.3 0.3 0.3 0.3 0.3 0.3 0.3 0.3 0.3 0.3 0.3 0.3 0.3 0.3 0.3 1.4 1.4 1.4 1.4 1.4 1.4 1.5 1.5 1.6 1.6 1.6 1.7 1.8 1.8 1.8 mm mm mm 1.0/1.0kV AC,1.5kV DC SiechemEBXLXLPO120°C GIWireBraidedCopperENSpecificationSolarCable GI Wire Catalogue No B567 TUV AS 9100 ISO 45001 ISO 9001 ISO 14001

RkJQdWJsaXNoZXIy NDgyMjA=