Silicone cable
Product Construction Wires & Cables Application Features Note : XX* & YY : Please add last two digits in the part number as per the colour code given hereunder replacing XX & YY while ordering. * Red - 01 Yellow - 02 Blue - 03 Black - 04 Green - 05 Yellow-Green - 06 Grey - 07 Brown - 08 White - 09 Orange - 10 Violet - 11 Chocolate - 12 Tan - 13 Charcoal - 14 LT Blue - 15 DK Grey - 16 LT Green - 17 DK Green - 18 DK Blue - 19 Purple - 20 Pink - 21 Technical Data ü Specification BS EN 50382-2:2008 ü Test Voltage 6.5 kV ü Maximum Operating 0 Temperature 120 C ü Working Voltage 1.8 / 3 kV ü Type FC as per BS EN 50382-2 F EI 111 (Insulation Material) C EM 105 (Sheath Material) 0 Siechem ATC Conductor, Silicone Insulated and Sheathed 1.8 / 3 kV Type FC 120 C Cable 36 www.siechem.com All information given are in good faith.Siechem's liability is only to replace the defective portion of cables provided the same is mutually established as manufacturing defects within the guarantee period as agreed in writing and Siechem shall not be liable for any compensation or damages. Siechem reserves the right to revise any of the above specifications without prior intimation. Subject to Chennai Jurisdiction. Catalogue No A109 ü Conductor : Annealed Tinned Class 5 Copper Conductor as per EN 60228 ü Insulation : EBXL - EI 111 as per EN 50382-1 ü Sheath : EBXL - EM 105 as per EN 50382-1 0 Siechem ATC Conductor, Silicone Insulated and Sheathed 1.8 / 3 kV Type FC 120 C Cable ü ü 1.3 1.3 1.3 1.3 1.5 1.5 1.8 1.8 1.8 1.8 2.2 2.2 2.2 2.4 2.4 2.4 2.6 2 mm mm mm Part Number Size Weight (Approx.) mm Kg/Km 1.5 2.5 4 6 10 16 25 35 50 70 95 120 150 185 240 300 400 Max. Conductor Resistance 0 at 20 C Ω /km Conductor Diameter mm 1.5 1.95 2.5 3.0 3.9 5.0 6.4 7.7 9.2 11.0 12.5 14.2 15.8 17.5 20.1 22.5 25.8 Overall Diameter mm Min Max 1.4 1.4 1.4 1.4 1.4 1.4 1.4 1.4 1.4 1.5 1.5 1.6 1.6 1.7 1.8 1.9 2.0 6.8 7.2 7.7 8.2 9.4 10.5 12.3 13.6 15.0 16.8 19.0 20.8 22.3 24.5 27.1 29.5 33.2 7.9 8.4 9.0 9.6 11.0 12.2 14.4 15.9 17.5 19.7 22.2 24.3 26.1 28.6 31.7 34.6 38.9 ü Halogen free ü Flame retardant ü Oil resistant ü Low temperature resistant ü Resistance to ozone, chemical oil and fuel ü Recommended for high temperature applications in railway vehicles (locomotives, trains, trolley buses) ü Used as power and control cables for protected installation inside & outside of rolling stock. ü Used in auxillary & main circuit wiring such as control panels, monitoring control, electric heating, lighting etc. : : : : : : Nominal Sheath Thickness Nominal Insulation Thickness A38513XXYY A38516XXYY A38519XXYY A38523XXYY A38527XXYY A38528XXYY A38530XXYY A38532XXYY A38534XXYY A38537XXYY A38538XXYY A38541XXYY A38542XXYY A38544XXYY A38546XXYY A38548XXYY A38549XXYY * 82 97 118 144 208 278 396 504 661 884 1171 1433 1729 2119 2672 3229 4144 13.7 8.21 5.09 3.39 1.95 1.24 0.795 0.565 0.393 0.277 0.210 0.164 0.132 0.108 0.0187 0.0654 0.0495 2D View AS 9100 ISO 45001 ISO 9001 ISO 14001
Made with FlippingBook
RkJQdWJsaXNoZXIy NDgyMjA=