Rubber cable

Wires & Cables Part Number Outer Diameter (mm) approx. Weight (Kg/Km) approx. 34 www.siechem.com All information given are in good faith.Siechem's liability is only to replace the defective portion of cables provided the same is mutually established as manufacturing defects within the guarantee period as agreed in writing and Siechem shall not be liable for any compensation or damages. Siechem reserves the right to revise any of the above specifications without prior intimation. Subject to Chennai Jurisdiction. Catalogue No 526 Thickness of Insulation (mm) Thickness of Outersheath (mm) Copper Index (Kg/Km) 1.0 1.2 1.2 1.4 1.4 1.6 1.6 1.8 1.8 2.0 2.2 2.4 2.6 2.8 2.0 2.4 2.5 3.2 3.3 3.5 3.6 3.8 4.0 4.2 4.3 4.6 4.9 5.2 15.08 18.54 20.92 25.69 28.32 32.57 36.31 40.78 44.50 48.99 53.38 60.03 66.20 74.35 103.37 172.29 275.66 430.72 603.01 861.44 1206.02 1636.74 2067.46 2584.32 3187.33 4134.92 5168.65 6891.53 332.39 514.75 698.56 1066.45 1355.68 1840.51 2386.61 3108.59 3786.28 4651.47 5617.52 7166.92 8822.38 11426.52 2C X 6 2C X 10 2C X 16 2C X 25 2C X 35 2C X 50 2C X 70 2C X 95 2C X 120 2C X 150 2C X 185 2C X 240 2C X 300 2C X 400 5262302 5262702 5262802 5263002 5263202 5263402 5263702 5263802 5264102 5264202 5264402 5264602 5264802 5264902 ü Temperature Range : 0 Insulation for General Service : 60 C 0 Heat Resisting Insulation : 90 C ü High Voltage Test : 3 kV for 5 mins ü Rated Voltage : 1.1 kV ü Specification : IS 9968 Part - 1 Product Construction Technical Data ü Conductor : Annealed Tinned Flexible Copper, Class 5. ü Separator Tape (Optional) ü Insulation : General Service Elastomeric, Type IE 1 as per IS 6380-1984 (Optional : Heat Resisting elastomer, Type IE 2 as per IS 6380-1984) ü Tape (Optional) ü Filling (Optional) ü Binder Tape : Optional ü Outer Sheath : For General Purpose Rubber Insulation Type SE 2 as per IS 6380-1984 (Optional - Heat Resisting Rubber Insulation, Type SE 4 as per IS 6380-1984) Siechem Annealed Tinned Copper Conductor Synthetic Elastomeric Insulated, Sheathed Multi Core Rubber Cable as per IS 9968 Part-1 SiechemAnnealed Tinned Copper Conductor Synthetic Elastomeric Insulated, Sheathed Multi Core Rubber Cable Application Features ü Used for measuring & controlling in control equipment for conveyors and control units ü Fixed installation and for flexible use when temporarily moved in medium mechanical condition ü Used outdoors when protected and in dry or moist conditions indoor. ü Suitable for many applications, including use in elevators, lifts, cranes, mines, heater leads, and electric iron leads etc. ü Flexible ü Abrasion Resistance ü High Dielectric Strength ü Flame Retardant ü Medium Mechanical Stress ü Long Cable life. st 1 time in India EBXL Rubber Cable as per IS 9968 with enhanced properties No.of Cores X Conductor size 2 (Nos X mm ) AS 9100 ISO 45001 ISO 9001 ISO 14001

RkJQdWJsaXNoZXIy NDgyMjA=