Rolling stock cable

Wires & Cables Application Product Construction Technical Data Siechem Sietrans GKW S FS 180 Fire Resistant Cables Part Number Cable Weight (Kg/Km) approx. ü Conductor : Annealed Tinned Flexible Copper Conductor ü Flame Barrier : Phlogopite Tape ü Insulation : Electron Beam Cross Linked Polyolefin Copolymer ü Insulation Colour : Grey Core with Number Printing ü Flame Barrier : Phlogopite Tape ü Outer Sheath : Electron Beam Cross Linked Elastomer Compound ü Sheath Colour :Black Catalogue No. A546 www.siechem.com All information given are in good faith.Siechem's liability is only to replace the defective portion of cables provided the same is mutually established as manufacturing defects within the guarantee period as agreed in writing and Siechem shall not be liable for any compensation or damages. Siechem reserves the right to revise any of the above specifications without prior intimation. Subject to Chennai Jurisdiction. ü Nominal voltage U /U : 0.3/0.5 kV AC ° ü Max. permissible (i) U : 0.36 kV AC om Operating voltage (ii) U : 0.6 kV AC m (iii) V : 0.45 kV DC ° (iv) V : 0.9 kV DC m ü Testing voltage : 2kV AC (50Hz / 5min) ü Max. conductor temperature : +120°C, 20,000 H ü Short circuit temperature : +280°C ü Min bending radius : OD < 10mm > 5 x Cable OD OD < 10mm > 6 x Cable OD ü Fire Safety Performance for Rolling Stock i) EN 45545-2 Hazard Level HL1- HL3 ii) EN 50264-1 ü Vertical flame : (i) EN 60332-1-2 - Single cable propagation (ii) EN 60332-3-24, EN 60332-3-25 & EN 50305 - Bunched cables ü Smoke density : EN 61034-2 ü Toxicity of gases : EN 50305 ü Halogen free : EN 50267-2-1 & EN 60684-2 ü Corrosivity of gases : EN 50267-2-2 ü Circuit integrity : EN 50200 : 120 minutes EN 60331-21 : 180 minutes ü Material Properties (as per EN 50264-3-2) ü High resistance to cold : EN 60811-504 ü High resistance to oil : EN 60811-404 ü High resistance to fuel : EN 60811-404 ü Resistance to ozone : EN 50264-3-2 ü Limiting oxygen index : ISO 4589-2, ASTM D 2863 ü For protected installation inside & outside of rail vehicles and buses. ü These cables also maintain their function over a limited period in the event of a fire and are suitable for connecting fixed and moving parts such as emergency lamps, flue gas outlets and switchgear. ü Fire Survival applications. Conductor Construction No of Strands X Strand Dia. (Nos) X (mm) No. of Cores X Cross Section 2 (Nos) X (mm ) Max Conductor 0 Resistance at 20 C ( Ω /km) 2 X 0.5 3 X 0.5 4 X 0.5 5 X 0.5 6 X 0.5 7 X 0.5 8 X 0.5 9 X 0.5 10 X 0.5 12 X 0.5 14 X 0.5 16 X 0.5 20 X 0.5 24 X 0.5 27 X 0.5 2 X 0.75 3 X 0.75 4 X 0.75 5 X 0.75 16 X 0.20 16 X 0.20 16 X 0.20 16 X 0.20 16 X 0.20 16 X 0.20 16 X 0.20 16 X 0.20 16 X 0.20 16 X 0.20 16 X 0.20 16 X 0.20 16 X 0.20 16 X 0.20 16 X 0.20 24 X 0.20 24 X 0.20 24 X 0.20 24 X 0.20 0.93 0.93 0.93 0.93 0.93 0.93 0.93 0.93 0.93 0.93 0.93 0.93 0.93 0.93 0.93 1.14 1.14 1.14 1.14 40.1 40.1 40.1 40.1 40.1 40.1 40.1 40.1 40.1 40.1 40.1 40.1 40.1 40.1 40.1 26.7 26.7 26.7 26.7 5.9 ± 0.6 6.2 ± 0.6 6.9 ± 0.7 7.6 ± 0.8 8.4 ± 0.8 8.6 ± 0.9 9.6 ± 1.0 10.4 ± 1.0 10.9 ± 1.1 11.4 ± 1.1 12.0 ± 1.2 12.7 ± 1.3 14.2 ± 1.4 15.7 ± 1.6 16.1 ± 1.6 6.5 ± 0.7 6.9 ± 0.7 7.7 ± 0.8 8.6 ± 0.9 52 61 75 89 108 119 139 160 176 199 226 255 313 375 408 65 77 97 117 Siechem Sietrans GKW S FS 180 2D View Features ü Maintains circuit integrity for 3 hours under fire condition. ü High temperature resistance for use -40°C up to +120°C ü Advance performance halogen free ü Oil and fuel resistance ü Electron beam cross-linked ü Halogen free ü Fire resistance Nominal Overall Diameter (mm) Nominal Conductor Diameter (mm) GKW S FS G K W S FS Electron Beam Cross linked Cold Resistant Heat Resistant Sheathed Fire Resistant A5460602 A5460603 A5460604 A5460605 A5460606 A5460607 A5460608 A5460609 A5460610 A5460612 A5460614 A5460616 A5460620 A5460624 A5460627 A5460802 A5460803 A5460804 A5460805 61 IATF 16949 AS 9100 ISO 45001 ISO 9001 ISO 14001 RDSO

RkJQdWJsaXNoZXIy NDgyMjA=