Rolling stock cable
Wires & Cables Application Product Construction Technical Data Siechem Sietrans GKW US FS 180 Fire Resistant Cables Part Number Cable Weight (Kg/Km) Approx. Siechem Sietrans GKW US FS 180 ü Conductor : Annealed Tinned Flexible Copper Conductor ü Flame Barrier : Phlogopite Tape ü Insulation : Electron Beam Cross Linked Polyolefin Copolymer ü Colour : Grey and as per customer order Features ü Maintains circuit integrity for 3 hours under fire condition. ü High temperature resistance for use -40°C up to +120°C ü Oil and fuel resistant ü Electron beam cross-linked ü Halogen free ü Fire resistance Catalogue No. A545 www.siechem.com All information given are in good faith.Siechem's liability is only to replace the defective portion of cables provided the same is mutually established as manufacturing defects within the guarantee period as agreed in writing and Siechem shall not be liable for any compensation or damages. Siechem reserves the right to revise any of the above specifications without prior intimation. Subject to Chennai Jurisdiction. ü Nominal voltage U /U : 0.3/0.5 kV AC ° ü Max. permissible : (i) U : 0.36 kV AC 0m operating voltage (ii) U : 0.6 kV AC m (iii) V : 0.45 kV DC ° (iv) V : 0.9 kV DC m ü Testing voltage : 2kV AC (50Hz / 5min) ü Max. conductor temperature : +120°C, 20,000 H ü Short circuit temperature : +280°C ü Min bending radius : > 3 X Cable OD ü Fire Safety Performance for Rolling Stock i) EN 45545-2 Hazard Level HL1- HL3 ii) EN 50264-1 ü Vertical flame : (i) EN 60332-1-2 - single cable propagation (ii) EN 50305 - Bunched cables ü Smoke density : EN 61034-2 ü Toxicity of gases : EN 50305 ü Halogen free : EN 50267-2-1 & EN 60684-2 ü Corrosivity of gases : EN 50267-2-2 ü Circuit integrity : EN 50200 : 120 minutes EN 60331-21 : 180 minutes ü Material Properties (as per EN 50264-3-2) ü Resistance to ozone : EN 50264-3-1 ü Resistance to oil : EN 50305 ü Resistance to fuel : EN 50305 ü Resistance to acid : EN 50264-3-1 ü Resistance to alkalis : EN 50264-3-1 ü Limiting oxygen index : ISO 4589-2, ASTM D 2863 GKW/ US FS G K W US FS Electron Beam Cross linked Cold Resistant Heat Resistant Unsheathed Fire resistant ü For Fixed and protected installation inside of rail vehicles. ü These cables maintain their function over a limited period in the event of a fire and suitable for connecting fixed and moving parts such as emergency lamps, flue gas outlets and switchgear. ü Fire Survival applications. Nominal Overall Diameter (mm) Nominal Conductor Diameter (mm) Conductor Construction No.of Strands X Strand dia (Nos) X (mm) No.of Cores X Cross Section 2 (Nos) X (mm ) Max Conductor 0 Resistance at 20 C ( Ω /km) 1 X 0.5 1 X 0.75 1 X 1 1 X 1.5 1 X 2.5 16 X 0.20 24 X 0.20 32 X 0.20 30 X 0.25 50 X 0.25 40.1 26.7 20.0 13.7 8.21 10 13 16 22 33 0.93 1.14 1.31 1.59 2.05 2.13 ± 0.2 2.34 ± 0.2 2.61 ± 0.3 2.88 ± 0.3 3.43 ± 0.3 2D View A54506XX A54508XX A54510XX A54513XX A54516XX 60 Note : XX* : Please add last two digits in the part number as per the colour code given hereunder replacing XX while ordering. Red - 01 Yellow - 02 Blue - 03 Black - 04 Green - 05 Yellow-Green - 06 Grey - 07 Brown - 08 White - 09 Orange - 10 Violet - 11 Chocolate - 12 Tan - 13 Charcoal - 14 LT Blue - 15 DK Grey - 16 LT Green - 17 DK Green - 18 DK Blue - 19 Purple - 20 Pink - 21 IATF 16949 AS 9100 ISO 45001 ISO 9001 ISO 14001 RDSO
Made with FlippingBook
RkJQdWJsaXNoZXIy NDgyMjA=