Rolling stock cable

Application Product Construction Technical Data 0 Siechem 3 GKW Multi Core 300/500V AC, 450/750 V DC, EBXL 120 C FS RW Rolling Stock Cable Siechem 3 GKW 300/500 V 7X0.5 MMS FS RW 2D View Wires & Cables Part Number Cable Weight (Kg/Km) approx. Nom. Outer Diameter (mm) All information given are in good faith.Siechem's liability is only to replace the defective portion of cables provided the same is mutually established as manufacturing defects within the guarantee period as agreed in writing and Siechem shall not be liable for any compensation or damages. Siechem reserves the right to revise any of the above specifications without prior intimation. Subject to Chennai Jurisdiction. 0 0 ü Temperature Range : -50 C to +120 C. ü Rated Voltage : 300/500V AC 450/750V DC ü Test voltage : 2 kV AC for 5 min. ü Specification : Generally as per BS EN 50306 & BS EN 50264-3-2 In addition to BS EN 50264-3-2 spec, cables also meet fire performance tests as per EN 45545 - 2 HL3 BS 6853 DIN 5510-2 NF F 16-101. Nom.Core Dia (mm) 16 X 0.20 16 X 0.20 16 X 0.20 16 X 0.20 16 X 0.20 16 X 0.20 16 X 0.20 16 X 0.20 24 X 0.20 24 X 0.20 24 X 0.20 24 X 0.20 24 X 0.20 24 X 0.20 24 X 0.20 24 X 0.20 24 X 0.20 32 X 0.20 32 X 0.20 32 X 0.20 32 X 0.20 32 X 0.20 30 X 0.25 30 X 0.25 30 X 0.25 30 X 0.25 30 X 0.25 30 X 0.25 30 X 0.25 30 X 0.25 50 X 0.25 50 X 0.25 Conductor Diameter (mm) 40.1 40.1 40.1 40.1 40.1 40.1 40.1 40.1 26.7 26.7 26.7 26.7 26.7 26.7 26.7 26.7 26.7 20.0 20.0 20.0 20.0 20.0 13.7 13.7 13.7 13.7 13.7 13.7 13.7 13.7 8.21 8.21 4.6 9.7 13 8.2 8.6 10.5 13 11.4 5.2 6.2 7.6 8.4 10.5 9.1 11.5 12.5 14.3 5.6 7.0 10.7 12.8 10.6 6.3 6.8 8.6 9.4 11.6 12.6 12.6 16.4 7.2 7.6 2 X 0.5 14 X 0.5 24 X 0.5 2 X 2 X 0.5 3 X 2 X 0.5 4 X 2 X 0.5 6 X 2 X 0.5 7 X 2 X 0.5 2 X 0.75 4 X 0.75 6 X 0.75 8 X 0.75 12 X 0.75 3 X 2 X 0.75 4 X 2 X 0.75 5 X 2 X 0.75 6 X 2 X 0.75 2 X 1 4 X 1 8 X 1 4 X 2 X 1 4 X 4 X 1 2 X 1.5 3 X 1.5 5G X 1.5 6 X 1.5 8 x 1.5 12 X 1.5 12G X 1.5 20 X 1.5 2 X 2.5 3 X 2.5 PH30A527W0602 PH30A527W0614 PH30A527W0624 PH30A527W0602P PH30A527W0603P PH30A527W0604P PH30A527W0606P PH30A527W0607P PH30A527W0802 PH30A527W0804 PH30A527W0806 PH30A527W0808 PH30A527W0812 PH30A527W0803P PH30A527W0804P PH30A527W0805P PH30A527W0806P PH30A527W1002 PH30A527W1004 PH30A527W1008 PH30A527W1004P PH30A527W1004Q PH30A527W1302 PH30A527W1303 PH30A527W1305G PH30A527W1306 PH30A527W1308 PH30A527W1312 PH30A527W1312G PH30A527W1320 PH30A527W1602 PH30A527W1603 0.90 0.90 0.90 0.90 0.90 0.90 0.90 0.90 1.10 1.10 1.10 1.10 1.10 1.10 1.10 1.10 1.10 1.22 1.22 1.22 1.22 1.22 1.50 1.50 1.50 1.50 1.50 1.50 1.50 1.50 1.94 1.94 2.00 2.00 2.00 2.00 2.00 2.00 2.00 2.00 2.25 2.25 2.25 2.25 2.25 2.25 2.25 2.25 2.25 2.50 2.50 2.50 2.50 2.50 2.80 2.80 2.80 2.80 2.80 2.80 2.80 2.80 3.20 3.20 6.0 ± 0.3 11.8 ± 0.4 15.5 ± 0.5 10.1 ± 0.4 10.5 ± 0.4 12.5 ± 0.4 15.2 ± 0.5 13.6 ± 0.4 6.4 ± 0.3 7.5 ± 0.3 9.05 ± 0.3 10.2 ± 0.4 12.4 ± 0.4 11.1 ± 0.4 13.7 ± 0.4 14.7± 0.4 16.9 ± 0.4 7.1 ± 0.3 8.5 ± 0.3 12.6 ± 0.4 15.0 ± 0.5 19.3 ± 0.5 7.8 ± 0.3 8.3 ± 0.3 10.5 ± 0.4 11.3 ± 0.4 13.9 ± 0.4 14.8 ± 0.4 14.8 ± 0.4 18.9 ± 0.5 8.8 ± 0.5 9.25 ± 0.3 59 230 370 140 170 210 310 270 70 97 140 170 250 176 260 300 380 85 130 270 310 562 110 130 196 230 347 400 400 640 140 170 Conductor Construction No of Strands X Strand dia (Nos X mm) No. of cores x Cross Section 2 (Nos) x (mm ) Max Conductor 0 Resistance at 20 C ( Ω /km) Screen Dia (mm) ü Conductor : Finely Stranded Annealed Electro Tinned Copper, Class 5 to EN 60228 ü Flame Barrier : Phlogopite tape ü Insulation : EBXL-LSZH Code M ü Core identification : Grey with Black numbered ü Screen : Tinned Copper Braid-S ü Separator Tape ü Outersheath : EBXL-LSZH (EM104) Code M Black colour or as per customer order. www.siechem.com 52 Catalogue No. PH30A527W Features ü Excellent resistance to high and low temperature ü Outstanding Flame retardant ü Halogen free ü Thin walled with excellent flexibility ü Resistance to oil, fuel, ozone, damp and humid weather conditions ü Smooth and abrasion resistant surface ü Easy to strip ü Low smoke density ü Soldering iron resistant ü High melting points for insulation ü Electron Beam Cross Linked. ü Resistance to corona effect. 3 GKW/T 3 G K W FS RW Rated Voltage (300/500V AC) Electron Beam Cross Linked Insulation Cold Resistant Heat Resistant Fire Survival Reduced insulation wall thickness ü For carriage wiring, terminal boxes, control panels, wiring harness in inside/outside the moving vehicle. ü For Rail/Bus and other transport vehicles. ü For switch gears and control gear manufacturing. IATF 16949 AS 9100 ISO 45001 ISO 9001 ISO 14001 RDSO

RkJQdWJsaXNoZXIy NDgyMjA=