Rolling stock cable
Catalogue No. 566 www.siechem.com All information given are in good faith.Siechem's liability is only to replace the defective portion of cables provided the same is mutually established as manufacturing defects within the guarantee period as agreed in writing and Siechem shall not be liable for any compensation or damages. Siechem reserves the right to revise any of the above specifications without prior intimation. Subject to Chennai Jurisdiction. 32 Application Product Construction Technical Data Siechem BS EN 50382-2 1.8 kV 1 x 185 FF 120 2D View Features Wires & Cables Cross Section 2 (mm ) Part Number Cable Weight (Kg/Km) approx. Note : XX* & YY* : Please add last two digits in the part number as per the colour code given hereunder replacing XX & YY while ordering. Red - 01 Yellow - 02 Blue - 03 Black - 04 Green - 05 Yellow-Green - 06 Grey - 07 Brown - 08 White - 09 Orange - 10 Violet - 11 Chocolate - 12 Tan - 13 Charcoal - 14 LT Blue - 15 DK Grey - 16 LT Green - 17 DK Green - 18 DK Blue - 19 Purple - 20 Pink - 21 0 Siechem BS EN 50382-2 Single Core, ATC Conductor, Silicone Insulated, Sheathed , 1.8/3kV Rated Type FF 120 C Rolling Stock Cable * 56613XXYY 56616XXYY 56619XXYY 56623XXYY 56627XXYY 56628XXYY 56630XXYY 56632XXYY 56634XXYY 56637XXYY 56638XXYY 56641XXYY 56642XXYY 56644XXYY 56646XXYY 56648XXYY 56649XXYY 30 X 0.25 50 X 0.25 56 X 0.30 84 X 0.30 80 X 0.40 126 X 0.40 196 X 0.40 276 X 0.40 396 X 0.40 360 X 0.50 475 X 0.50 608 X 0.50 756 X 0.50 925 X 0.50 1221 X 0.50 1525 X 0.50 2013 X 0.50 Insulation Thickness (mm) (Nom) Sheath Thickness (mm) (Nom) 1.5 2.5 4 6 10 16 25 35 50 70 95 120 150 185 240 300 400 Conductor Construction No.of Strands x Strand dia. (Nos x mm) ü Specification : BS EN 50382-2 : 2008 ü Hazard Level Classification as per EN 45545-2, HL3 ü Test voltage : 6.5kV 0 ü Maximum Operating Temperature : 120 C ü Rated Voltage : 1.8/3kV ü Type FF as per BS EN 50382-2 F : EI 111 (Insulation Material) F : EM 106 (Sheath Material) ü Cables also meet fire performance tests as per DIN 5510-2 BS 6853 NF F 16-101 1.3 1.3 1.3 1.3 1.5 1.5 1.8 1.8 1.8 1.8 2.2 2.2 2.2 2.4 2.4 2.4 2.6 13.7 8.21 5.09 3.39 1.95 1.24 0.795 0.565 0.393 0.277 0.210 0.164 0.132 0.108 0.0817 0.0654 0.0495 ü Conductor : Annealed Tinned Copper Class 5 Conductor as per EN 60228 ü Insulation : EI 111(Silicone) with properties according to BS EN 50382-1 ü Sheath : EM 106 (Silicone) with properties according to BS EN 50382-1 (Min) (Max) 1.4 1.4 1.4 1.4 1.4 1.4 1.4 1.4 1.4 1.5 1.5 1.6 1.6 1.7 1.8 1.9 2.0 6.8 7.2 7.7 8.2 9.4 10.5 12.3 13.6 15.0 16.8 19.0 20.8 22.3 24.5 27.1 29.5 33.2 7.9 8.4 9.0 9.6 11.0 12.2 14.4 15.9 17.5 19.7 22.2 24.3 26.1 28.6 31.7 34.6 38.9 78 93 113 137 199 265 377 479 627 837 1119 1366 1644 2001 2520 3040 3894 ü Recommended for high temperature applications in railway vehicles (locomotives, trains, trolley buses) ü Used as power and control cables for protected installation inside & outside of rolling stock ü Used in auxillary & main circuit wiring such as control panels, monitoring control, electric heating, lighting etc. Max. Conductor Resistance 0 at 20 C ( Ω /km) Overall Diameter (mm) ü Halogen free. ü Flame retardant. ü Oil resistant. ü Low temperature resistant. ü Excellent flexibility. ü Low smoke density. ü Resistance to ozone, chemical oil and fuel. IATF 16949 AS 9100 ISO 45001 ISO 9001 ISO 14001 RDSO
Made with FlippingBook
RkJQdWJsaXNoZXIy NDgyMjA=