Rolling stock cable

Catalogue No. 565 www.siechem.com All information given are in good faith.Siechem's liability is only to replace the defective portion of cables provided the same is mutually established as manufacturing defects within the guarantee period as agreed in writing and Siechem shall not be liable for any compensation or damages. Siechem reserves the right to revise any of the above specifications without prior intimation. Subject to Chennai Jurisdiction. 31 Application Product Construction Technical Data 0 Siechem BS EN 50382-2 Single Core, ATC Conductor, Silicone Insulated Unsheathed, 1.8/3kV, Rated Type F 120 C Rolling Stock Cable Cross Section 2 (mm ) Part Number Cable Weight (Kg/Km) approx. ü Specification : BS EN 50382-2 : 2008 ü Hazard Level Classification as per EN 45545-2, HL3 ü Test voltage : 6.5 kV 0 ü Maximum Operating Temperature : 120 C ü Rated Voltage : 1.8/3 kV ü Type F as per BS EN 50382-2 F : EI 111 (Insulation Material) ü Cables also meet fire performance tests as per DIN 5510-2 BS 6853 NF F 16-101 Siechem BS EN 50382-2 1.8 kV 1 x 150 F 120 2D View Wires & Cables Note : XX* : Please add last two digits in the part number as per the colour code given hereunder replacing XX while ordering. Red - 01 Yellow - 02 Blue - 03 Black - 04 Green - 05 Yellow-Green - 06 Grey - 07 Brown - 08 White - 09 Orange - 10 Violet - 11 Chocolate - 12 Tan - 13 Charcoal - 14 LT Blue - 15 DK Grey - 16 LT Green - 17 DK Green - 18 DK Blue - 19 Purple - 20 Pink - 21 * 56513XX 56516XX 56519XX 56523XX 56527XX 56528XX 56530XX 56532XX 56534XX 56537XX 56538XX 56541XX 56542XX 56544XX 56546XX 56548XX 56549XX 30 X 0.25 50 X 0.25 56 X 0.30 84 X 0.30 80 X 0.40 126 X 0.40 196 X 0.40 276 X 0.40 396 X 0.40 360 X 0.50 475 X 0.50 608 X 0.50 756 X 0.50 925 X 0.50 1221 X 0.50 1525 X 0.50 2013 X 0.50 Insulation Thickness (mm) (Nom) 1.5 2.5 4 6 10 16 25 35 50 70 95 120 150 185 240 300 400 Conductor Construction No.of Strands x Strand dia. (Nos x mm) 2.5 2.5 2.5 2.5 2.5 2.5 2.5 2.5 2.5 2.5 2.7 2.7 2.7 2.7 2.7 2.7 2.9 13.7 8.21 5.09 3.39 1.95 1.24 0.795 0.565 0.393 0.277 0.210 0.164 0.132 0.108 0.0817 0.0654 0.0495 ü Conductor : Annealed Tinned Copper Class 5 Conductor as per EN 60228 ü Insulation : EI 111 (Silicone) with properties according to BS EN 50382-1 Overall Diameter (mm) (Min) (Max) 6.3 6.7 7.2 7.7 8.5 9.6 10.9 12.1 13.5 15.2 17.0 18.6 20.1 21.7 24.1 26.4 29.9 7.3 7.8 8.4 9.0 10.0 11.2 12.7 14.1 15.8 17.8 19.9 21.7 23.5 25.4 28.2 30.9 34.9 ü Recommended for high temperature applications in railway vehicles (locomotives, trains, trolley buses) ü Used as power and control cables for protected installation inside & outside of rolling stock ü Used in auxillary & main circuit wiring such as control panels, monitoring control, electric heating, lighting etc. 64 78 97 120 169 232 322 418 559 744 994 1220 1487 1794 2277 2775 3610 Features ü Halogen free. ü Flame retardant. ü Oil resistant. ü Low temperature resistant. ü Excellent flexibility. ü Low smoke density. ü Resistance to ozone, chemical oil and fuel. Max. Conductor Resistance 0 at 20 C ( Ω /km) IATF 16949 AS 9100 ISO 45001 ISO 9001 ISO 14001 RDSO

RkJQdWJsaXNoZXIy NDgyMjA=