Rolling stock cable
Application Product Construction Technical Data 0 Siechem BS EN 50264-3-1 Single Core, Sheathed, 3600/6000V AC, 5400V DC, EBXL 90 C Rolling Stock Cable ü Conductor : Finely Stranded Annealed Electro Tinned Copper, Class 5. ü Insulation : EBXL - EI109 ü Outersheath : EBXL - EM 104 ü Colour : Black or as per customer order. 2D View Features ü Excellent resistance to high and low temperature ü Outstanding Flame retardant ü Halogen free ü Thin walled with excellent flexibility ü Resistance to oil, fuel, ozone and weathering. ü Easy to strip ü Low smoke density ü Soldering iron resistant ü Electron Beam Cross Linked. ü Resistance to corona effect. Wires & Cables Catalogue No. 564 www.siechem.com All information given are in good faith.Siechem's liability is only to replace the defective portion of cables provided the same is mutually established as manufacturing defects within the guarantee period as agreed in writing and Siechem shall not be liable for any compensation or damages. Siechem reserves the right to revise any of the above specifications without prior intimation. Subject to Chennai Jurisdiction. 30 Cross Section 2 (mm ) Part Number Cable Weight (Kg/Km) approx. Outer Diameter (mm) Conductor Diameter (mm) (Nom) Siechem EN 50264-3-1 3600V 50 MM Note : XX* & YY* : Please add last two digits in the part number as per the colour code given hereunder replacing XX & YY while ordering, for Insulation and Sheath respectively. Red - 01 Yellow - 02 Blue - 03 Black - 04 Green - 05 Yellow-Green - 06 Grey - 07 Brown - 08 White - 09 Orange - 10 Violet - 11 Chocolate - 12 Tan - 13 Charcoal - 14 LT Blue - 15 DK Grey - 16 LT Green - 17 DK Green - 18 DK Blue - 19 Purple - 20 Pink - 21 * 56416XXYY 56419XXYY 56423XXYY 56427XXYY 56428XXYY 56430XXYY 56432XXYY 56434XXYY 56437XXYY 56438XXYY 56441XXYY 56442XXYY 56444XXYY 56446XXYY 56448XXYY 56449 XXYY 1.95 2.5 3.0 3.9 5.0 6.4 7.7 9.2 11.0 12.5 14.2 15.8 17.5 20.1 22.5 25.8 50 X 0.25 56 X 0.30 84 X 0.30 80 X 0.40 126 X 0.40 196 X 0.40 276 X 0.40 396 X 0.40 360 X 0.50 475 X 0.50 608 X 0.50 756 X 0.50 925 X 0.50 1221 X 0.50 1525 X 0.50 2013 X 0.50 Insulation Thickness (mm) (Nom) Sheath Thickness (mm) (Nom) 2.6 2.6 2.6 2.6 2.6 2.9 2.9 2.9 2.9 2.9 2.9 2.9 3.2 3.4 3.4 3.4 0.8 0.8 0.8 0.8 0.8 1.0 1.0 1.0 1.0 1.0 1.2 1.2 1.2 1.4 1.4 1.4 2.5 4 6 10 16 25 35 50 70 95 120 150 185 240 300 400 8.21 5.09 3.39 1.95 1.24 0.795 0.565 0.393 0.277 0.210 0.164 0.132 0.108 0.0817 0.0654 0.0495 130 150 180 225 300 435 540 695 900 1140 1400 1680 2055 2635 3113 4200 Conductor Construction No.of Strands x Strand dia. (Nos x mm) Max. Conductor Resistance 0 at 20 C ( Ω /km) (Max) (Min) 8.6 9.1 9.6 10.4 11.5 13.7 14.9 16.4 18.0 19.5 21.4 22.9 25.1 28.3 30.6 33.7 10.1 10.7 11.2 12.2 13.4 16.1 17.5 19.1 21.1 22.8 25.1 26.8 29.4 33.1 35.8 39.4 0 0 ü Temperature Range : -40 C to +90 C. ü Rated Voltage : 3600/6000V AC ü Specification : BS EN 50264-3-1 ü Hazard Level Classification as per EN 45545-2, HL3 Conductor : BS EN 60228, Class 5 In addition to BS EN 50264 spec, cables also meet fire performance tests as per UNI CEI 11170-3 DIN 5510-2 NF F 16-101 CEN /TS 45545 ü For mechanically protected installation in Rail / Bus and other transport vehicles. ü Cables are used in Driver desks, Control panels, wiring harness in inside/outside the moving vehicles. IATF 16949 AS 9100 ISO 45001 ISO 9001 ISO 14001 RDSO
Made with FlippingBook
RkJQdWJsaXNoZXIy NDgyMjA=