Rolling stock cable
Wires & Cables Application Product Construction Technical Data ü Conductor : Finely Stranded Annealed Electro Tinned Copper, Class 5. ü Insulation : EBXL - EI 109 ü Screen : Tinned Copper Braid ü Separator Tape ü Outersheath :EBXL - EM 104 ü Colour : Black or as per customer order 0 0 ü Temperature Range : -40 C to +90 C. ü Rated Voltage : 600/1000V AC 900V DC ü Specification : BS EN 50264-3-2, Table 9 ü Hazard Level Classification as per EN 45545-2, HL3 Conductor : BS EN 60228,Class 5 Cable Ref : Table 3 to Table 7 In addition to BS EN 50264 spec, cables also meet fire performance tests as per UNI CEI 11170-3 DIN 5510-2 NF F 16-101 CEN /TS 45545 0 Siechem BS EN 50264-3-2 Multi Core, Screened, 600/1000V AC, 900V DC, EBXL 90 C Rolling Stock Cable Siechem EN 50264-3-2 600V 4 X 1.5 MM S ü For mechanically protected installation in Rail / Bus and other transport vehicles. ü Cables are used in Driver desks, Control panels, wiring harness in inside/outside the moving vehicles. 2D View Features ü Excellent resistance to high and low temperature ü Outstanding Flame retardant ü Halogen free ü Thin walled with excellent flexibility ü Resistance to oil, fuel, ozone and weathering. ü Easy to strip ü Low smoke density ü Soldering iron resistant ü Electron Beam Cross Linked. ü Resistance to corona effect. Catalogue No. 563 www.siechem.com All information given are in good faith.Siechem's liability is only to replace the defective portion of cables provided the same is mutually established as manufacturing defects within the guarantee period as agreed in writing and Siechem shall not be liable for any compensation or damages. Siechem reserves the right to revise any of the above specifications without prior intimation. Subject to Chennai Jurisdiction. 29 Part Number Cable Weight (Kg/Km) approx. Outer Diameter (mm) Max. Core Diameter (mm) 5631302 5631303 5631304 5631602 5631603 5631604 5631902 5631903 5631904 5632302 5632303 5632304 5632702 5632703 5632704 5632802 5632803 5632804 5633002 5633003 5633004 5633202 5633203 C1763204 5633402 5633403 C1763404 3.3 3.3 3.3 3.8 3.8 3.8 4.4 4.4 4.4 5.0 5.0 5.0 5.9 5.9 5.9 7.2 7.2 7.2 9.1 9.1 9.1 10.6 10.6 10.6 12.4 12.4 12.4 2 X 1.5 3 X 1.5 4 X 1.5 2 X 2.5 3 X 2.5 4 X 2.5 2 X 4 3 X 4 4 X 4 2 X 6 3 X 6 4 X 6 2 X 10 3 X 10 4 X 10 2 X 16 3 X 16 4 X 16 2 X 25 3 X 25 4 X 25 2 X 35 3 X 35 3 X 35+25 2 X 50 3 X 50 3 X 50+25 13.7 13.7 13.7 8.21 8.21 8.21 5.09 5.09 5.09 3.39 3.39 3.39 1.95 1.95 1.95 1.24 1.24 1.24 0.795 0.795 0.795 0.565 0.565 0.565 0.393 0.393 0.393 7.9 8.4 9.1 8.7 9.2 10.4 10.2 10.8 11.8 10.9 11.6 13.1 13.4 14.4 15.9 16.0 17.4 19.3 19.8 21.3 24.0 22.8 24.5 26.9 26.4 28.3 31.5 1.5 1.5 1.5 1.95 1.95 1.95 2.5 2.5 2.5 3.0 3.0 3.0 3.9 3.9 3.9 5.0 5.0 5.0 6.4 6.4 6.4 7.7 7.7 7.7 9.2 9.2 9.2 Insulation Thickness (mm) (Nom) 0.7 0.7 0.7 0.7 0.7 0.7 0.7 0.7 0.7 0.7 0.7 0.7 0.7 0.7 0.7 0.7 0.7 0.9 0.9 0.9 0.9 0.9 0.9 0.9 1.0 1.0 1.0 Outer Sheath Thickness (mm) (Nom) 0.70 0.70 0.70 0.70 0.70 0.80 0.80 0.80 0.80 0.80 0.80 1.00 1.00 1.00 1.00 1.00 1.20 1.20 1.20 1.20 1.40 1.40 1.40 1.40 1.40 1.60 1.60 135 160 190 170 205 265 240 285 345 300 365 465 430 535 680 615 770 975 910 1150 1485 1200 1550 1845 1635 2130 2450 Max. Wire Diameter of Screen (mm) 0.16 0.16 0.16 0.16 0.16 0.21 0.21 0.21 0.21 0.21 0.21 0.21 0.21 0.26 0.26 0.26 0.26 0.26 0.26 0.26 0.31 0.31 0.31 0.31 0.31 0.31 0.31 Conductor Diameter (mm) No. of cores x Cross Section 2 (Nos) x (mm ) Max. Conductor Resistance 0 at 20 C ( Ω /km) 9.9 10.4 11.3 10.7 11.4 12.9 12.7 13.3 14.5 13.6 14.3 16.1 16.6 18.0 19.5 19.8 21.3 23.6 24.6 26.1 29.3 27.9 29.8 32.9 32.3 34.6 38.2 (Min) (Max) IATF 16949 AS 9100 ISO 45001 ISO 9001 ISO 14001 RDSO
Made with FlippingBook
RkJQdWJsaXNoZXIy NDgyMjA=