Rolling stock cable
Wires & Cables www.siechem.com All information given are in good faith.Siechem's liability is only to replace the defective portion of cables provided the same is mutually established as manufacturing defects within the guarantee period as agreed in writing and Siechem shall not be liable for any compensation or damages. Siechem reserves the right to revise any of the above specifications without prior intimation. Subject to Chennai Jurisdiction. 28 Application Product Construction Technical Data 0 0 ü Temperature Range : -40 C to +90 C. ü Rated Voltage : 600/1000V AC ü Specification : BS EN 50264-3-2, Table 8 ü Hazard Level Classification as per EN 45545-2, HL3 Conductor : BS EN 60228, Class 5 Cable Ref : Table 3 to Table 7 In addition to BS EN 50264 spec, cables also meet fire performance tests as per UNI CEI 11170-3 DIN 5510-2 NF F 16-101 CEN /TS 45545 0 Siechem BS EN 50264-3-2 Multi Core, 600/1000V AC, EBXL 90 C Rolling Stock Cable Part Number Cable Weight (Kg/Km) approx. Outer Diameter (mm) Max. Core Diameter (mm) ü Conductor : Finely Stranded Annealed Electro Tinned Copper, Class 5. ü Insulation : EBXL - EI 109 ü Separator : Polyester Tape ü Outer Sheath : EBXL - EM 104 ü Colour : Black or as per customer order ü For mechanically protected installation in Rail / Bus and other transport vehicles. ü Cables are used in Driver desks, Control panels, wiring harness in inside/outside the moving vehicles. Siechem EN 50264-3-2 600 V 4 x 1.5 MM 2D View Features ü Excellent resistance to high and low temperature ü Outstanding Flame retardant ü Halogen free ü Thin walled with excellent flexibility ü Resistance to oil, fuel, ozone and weathering. ü Easy to strip ü Low smoke density ü Soldering iron resistant ü Electron Beam Cross Linked. ü Resistance to corona effect. Insulation Thickness (mm) (Nom) Outer sheath Thickness (mm) (Nom) Conductor Diameter (mm) No. of cores x Cross Section 2 (Nos) x (mm ) (Min) (Max) 5621302 5621303 5621304 5621602 5621603 5621604 5621902 5621903 5621904 5622302 5622303 5622304 5622702 5622703 5622704 5622802 5622803 5622804 5623002 5623003 5623004 5623202 5623203 C1753204 5623402 5623403 C1753404 2 X 1.5 3 X 1.5 4 X 1.5 2 X 2.5 3 X 2.5 4 X 2.5 2 X 4 3 X 4 4 X 4 2 X 6 3 X 6 4 X 6 2 X 10 3 X 10 4 X 10 2 X 16 3 X 16 4 X 16 2 X 25 3 X 25 4 X 25 2 X 35 3 X 35 3 X 35+25 2 X 50 3 X 50 3 X 50+25 1.5 1.5 1.5 1.95 1.95 1.95 2.5 2.5 2.5 3.0 3.0 3.0 3.9 3.9 3.9 5.0 5.0 5.0 6.4 6.4 6.4 7.7 7.7 7.7 9.2 9.2 9.2 13.7 13.7 13.7 8.21 8.21 8.21 5.09 5.09 5.09 3.39 3.39 3.39 1.95 1.95 1.95 1.24 1.24 1.24 0.795 0.795 0.795 0.565 0.565 0.565 0.393 0.393 0.393 0.70 0.70 0.70 0.70 0.70 0.70 0.70 0.70 0.70 0.70 0.70 0.70 0.70 0.70 0.70 0.70 0.70 0.70 0.90 0.90 0.90 0.90 0.90 0.90 1.00 1.00 1.00 3.3 3.3 3.3 3.8 3.8 3.8 4.4 4.4 4.4 5.0 5.0 5.0 5.9 5.9 5.9 7.2 7.2 7.2 9.1 9.1 9.1 10.6 10.6 10.6 12.4 12.4 12.4 7.2 7.7 8.5 8.0 8.5 9.4 9.1 9.7 10.9 10.1 10.7 12.2 12.5 13.3 14.7 14.9 16.0 18.0 18.7 20.0 22.6 21.2 23.0 25.7 25.1 26.3 30.0 0.70 0.70 0.70 0.70 0.70 0.70 0.70 0.70 0.80 0.80 0.80 1.00 1.00 1.00 1.00 1.00 1.00 1.20 1.20 1.20 1.40 1.20 1.20 1.40 1.40 1.40 1.60 9.0 9.5 10.5 10.0 10.5 11.6 11.3 12.0 13.4 12.4 13.2 14.9 15.4 16.5 18.2 18.4 19.6 22.1 23.0 24.7 27.6 25.9 28.2 31.2 30.7 32.2 36.5 100 115 135 135 155 190 180 205 265 240 280 380 360 440 555 510 660 855 905 985 1280 1030 1350 1630 1440 1890 2190 Catalogue No. 562 Max. Conductor Resistance 0 at 20 C ( Ω /km) IATF 16949 AS 9100 ISO 45001 ISO 9001 ISO 14001 RDSO
Made with FlippingBook
RkJQdWJsaXNoZXIy NDgyMjA=