Rolling stock cable

Wires & Cables Catalogue No. 587 www.siechem.com All information given are in good faith.Siechem's liability is only to replace the defective portion of cables provided the same is mutually established as manufacturing defects within the guarantee period as agreed in writing and Siechem shall not be liable for any compensation or damages. Siechem reserves the right to revise any of the above specifications without prior intimation. Subject to Chennai Jurisdiction. 27 Application Product Construction Technical Data 0 0 ü Temperature Range : -40 C to +90 C. ü Rated Voltage : 300/500V AC ü Specification : BS EN 50264-3-2 : 2008, Table 2 ü Hazard Level Classification as per EN 45545-2, HL3 Conductor : BS EN 60228, Class 5 In addition to BS EN 50264 spec, cables also meet fire performance tests as per UNI CEI 11170-3 DIN 5510-2 NF F 16-101 CEN /TS 45545 0 Siechem BS EN 50264-3-2 Multi Core, Screened 300/500 V AC, EBXL 90 C Rolling Stock Cable Part Number Cable Weight (Kg/Km) approx. Outer Diameter (mm) Max.Core Diameter (mm) Max. Wire Diameter of Screen (mm) ü Conductor : Finely Stranded Annealed Electro Tinned Copper, Class 5. ü Insulation : EBXL - EI 109 ü Screen : Tinned Copper Braid ü Separator Tape ü Outer Sheath : EBXL - EM 104 ü Colour : Black or as per customer order ü For mechanically protected installation in Rail / Bus and other transport vehicles. ü Cables are used in Driver desks, Control panels, wiring harness in inside/outside the moving vehicles. 2D View Features ü Excellent resistance to high and low temperature ü Outstanding Flame retardant ü Halogen free ü Thin walled with excellent flexibility ü Resistance to oil, fuel, ozone and weathering. ü Easy to strip ü Low smoke density ü Soldering iron resistant ü Electron Beam Cross Linked. ü Resistance to corona effect. 5871002 5871004 5871007 5871009 5871012 5871019 5871024 5871032 5871037 5871040 5871304 5871307 5871309 5871312 5871319 5871324 5871332 5871337 5871604 5871607 5871609 5871612 5871619 5871624 2.4 2.4 2.4 2.4 2.4 2.4 2.4 2.4 2.4 2.4 2.9 2.9 2.9 2.9 2.9 2.9 2.9 2.9 3.4 3.4 3.4 3.4 3.4 3.4 0.16 0.16 0.16 0.21 0.21 0.26 0.26 0.26 0.26 0.26 0.16 0.21 0.21 0.21 0.26 0.26 0.26 0.26 0.21 0.21 0.26 0.26 0.26 0.26 2 X 1 4 X 1 7 X 1 9 X 1 12 X 1 19 X 1 24 X 1 32 X 1 37 X 1 40 X 1 4 X 1.5 7 X 1.5 9 X 1.5 12 X 1.5 19 X 1.5 24 X 1.5 32 X 1.5 37 X 1.5 4 X 2.5 7 X 2.5 9 X 2.5 12 X 2.5 19 X 2.5 24 X 2.5 20.0 20.0 20.0 20.0 20.0 20.0 20.0 20.0 20.0 20.0 13.7 13.7 13.7 13.7 13.7 13.7 13.7 13.7 8.21 8.21 8.21 8.21 8.21 8.21 6.0 7.0 8.2 10.2 10.9 13.2 15.2 16.6 17.2 18.2 8.0 9.6 12.1 13.0 15.3 18.1 19.8 20.5 9.2 11.1 13.9 15.0 17.8 20.6 1.25 1.25 1.25 1.25 1.25 1.25 1.25 1.25 1.25 1.25 1.5 1.5 1.5 1.5 1.5 1.5 1.5 1.5 1.95 1.95 1.95 1.95 1.95 1.95 Insulation Thickness (mm) (Nom) 0.4 0.4 0.4 0.4 0.4 0.4 0.4 0.4 0.4 0.4 0.5 0.5 0.5 0.5 0.5 0.5 0.5 0.5 0.5 0.5 0.5 0.5 0.5 0.5 Outer sheath Thickness (mm) (Nom) 0.6 0.7 0.7 0.8 0.8 1.0 1.0 1.0 1.0 1.2 0.7 0.7 1.0 1.0 1.0 1.2 1.2 1.2 0.7 0.8 1.0 1.0 1.2 1.2 Conductor Diameter (mm) No. of cores x Cross Section 2 (Nos) x (mm ) (Min) 7.1 8.2 9.6 11.9 12.7 15.4 17.8 19.4 20.1 21.3 9.4 11.3 14.2 15.2 17.9 21.2 23.2 24.0 10.8 13.0 16.3 17.5 20.8 24.1 (Max) Siechem EN 50264-3-2 300 V 4 x 1 MM S Max. Conductor Resistance 0 at 20 C ( Ω /km) 83 115 165 235 275 420 525 650 720 790 155 235 325 390 575 740 920 1025 215 325 460 555 815 1025 IATF 16949 AS 9100 ISO 45001 ISO 9001 ISO 14001 RDSO

RkJQdWJsaXNoZXIy NDgyMjA=