Rolling stock cable

Wires & Cables Catalogue No. 561 www.siechem.com All information given are in good faith.Siechem's liability is only to replace the defective portion of cables provided the same is mutually established as manufacturing defects within the guarantee period as agreed in writing and Siechem shall not be liable for any compensation or damages. Siechem reserves the right to revise any of the above specifications without prior intimation. Subject to Chennai Jurisdiction. 25 Application Product Construction Technical Data 0 0 ü Temperature Range : -40 C to +90 C. ü Rated Voltage : 1800/3000V AC ü Specification : BS EN 50264-3-1 ü Hazard Level Classification as per EN 45545-2, HL3 Conductor : BS EN 60228, Class 5 In addition to BS EN 50264 spec, cables also meet fire performance tests as per UNI CEI 11170-3 DIN 5510-2 NF F 16-101 CEN /TS 45545 0 Siechem BS EN 50264-3-1 Single Core, Sheathed 1800/3000V AC, 2700V DC EBXL 90 C Rolling Stock Cable ü Conductor : Finely Stranded Annealed Electro Tinned Copper, Class 5. ü Insulation : EBXL - EI 109 ü Outer Sheath : EBXL - EM 104 ü Colour : Black or as per customer order 2D View Features ü Excellent resistance to high and low temperature ü Outstanding Flame retardant ü Halogen free ü Thin walled with excellent flexibility ü Resistance to oil, fuel, ozone and weathering. ü Easy to strip ü Low smoke density ü Soldering iron resistant ü Electron Beam Cross Linked. ü Resistance to corona effect. Cross Section 2 (mm ) Part Number Cable Weight (Kg/Km) approx. Outer Diameter (mm) Note : XX* & YY* : Please add last two digits in the part number as per the colour code given hereunder replacing XX & YY while ordering, for Insulation and Sheath respectively. Red - 01 Yellow - 02 Blue - 03 Black - 04 Green - 05 Yellow-Green - 06 Grey - 07 Brown - 08 White - 09 Orange - 10 Violet - 11 Chocolate - 12 Tan - 13 Charcoal - 14 LT Blue - 15 DK Grey - 16 LT Green - 17 DK Green - 18 DK Blue - 19 Purple - 20 Pink - 21 * 30 x 0.25 50 x 0.25 56 x 0.30 84 x 0.30 80 x 0.40 126 x 0.40 196 x 0.40 276 x 0.40 396 x 0.40 360 x 0.50 475 x 0.50 608 x 0.50 756 x 0.50 925 x 0.50 1221 x 0.50 1525 x 0.50 2013 x 0.50 56113XXYY 56116XXYY 56119XXYY 56123XXYY 56127XXYY 56128XXYY 56130XXYY 56132XXYY 56134XXYY 56137XXYY 56138XXYY 56141XXYY 56142XXYY 56144XXYY 56146XXYY 56148XXYY 56149XXYY 13.7 8.21 5.09 3.39 1.95 1.24 0.795 0.565 0.393 0.277 0.210 0.164 0.132 0.108 0.0817 0.0654 0.0495 1.5 1.95 2.5 3.0 3.9 5.0 6.4 7.7 9.2 11.0 12.5 14.2 15.8 17.5 20.1 22.5 25.8 Insulation Thickness (mm) (Nom) 1.3 1.3 1.3 1.3 1.5 1.5 1.8 1.8 1.8 1.8 2.2 2.2 2.2 2.4 2.4 2.4 2.6 58 70 90 110 165 230 355 455 610 820 1080 1315 1610 1965 2465 3000 3980 1.5 2.5 4 6 10 16 25 35 50 70 95 120 150 185 240 300 400 Conductor Construction No.of Strands x Strand dia. (Nos x mm) Sheath Thickness (mm) (Nom) 0.8 0.8 0.8 0.8 0.8 0.8 1.0 1.0 1.0 1.0 1.0 1.0 1.2 1.2 1.2 1.2 1.4 Siechem EN 50264-3-1 1800 V 50 MM Max. Conductor 0 Resistance at 20 C ( Ω /km) (Min) (Max) 5.7 6.0 6.5 7.0 8.2 9.2 11.5 12.7 14.1 15.8 18.0 19.6 21.4 23.4 25.9 28.1 32.0 6.7 7.0 7.6 8.1 9.6 10.8 13.4 14.9 16.5 18.5 21.0 22.9 25.1 27.4 30.3 32.9 37.4 ü For mechanically protected installation in Rail / Bus and other transport vehicles. ü Cables are used in Driver desks, Control panels, wiring harness in inside/outside the moving vehicles. Conductor Diameter (mm) (Nom) IATF 16949 AS 9100 ISO 45001 ISO 9001 ISO 14001 RDSO

RkJQdWJsaXNoZXIy NDgyMjA=