Rolling stock cable

Application Product Construction Technical Data 0 Siechem BS EN 50306-4 7E Multi Pair, Screened, 300V AC, 450V DC, EBXL 90 C Rolling Stock Cable Part Number Cable Weight (Kg/Km) approx. Outer Diameter (mm) Siechem EN 50306-4 7E 300V 2 x 2 x 0.5 MM S 90 0 0 ü Temperature Range : -40 C to +90 C. ü Rated Voltage : 300V AC 450V DC ü Specification : BS EN 50306-4 : 2020, Table 7, Class E ü Hazard Level Classification as per EN 45545-2, HL3 Screened and Sheathed Pairs : EN50306-3 : 2020 Conductor : BS EN 50306-2 : 2020 In addition to BS EN 50306 spec, cables also meet fire performance tests as per UNI CEI 11170-3 DIN 5510-2 NF F 16-101 CEN /TS 45545 2D View Features ü Excellent resistance to high and low temperature ü Outstanding Flame retardant ü Halogen free ü Thin walled with excellent flexibility ü Resistance to oil, fuel, ozone and weathering. ü Easy to strip ü Low smoke density ü Soldering iron resistant ü Electron Beam Cross Linked. ü Resistance to corona effect. Wires & Cables Catalogue No. RA538 www.siechem.com All information given are in good faith.Siechem's liability is only to replace the defective portion of cables provided the same is mutually established as manufacturing defects within the guarantee period as agreed in writing and Siechem shall not be liable for any compensation or damages. Siechem reserves the right to revise any of the above specifications without prior intimation. Subject to Chennai Jurisdiction. 22 RA5380602P RA5380603P RA5380604P RA5380607P RA5380802P RA5380803P RA5380804P RA5380807P RA5381002P RA5381003P RA5381004P RA5381007P RA5381302P RA5381303P RA5381304P RA5381307P C2050606P 2 X 2 X 0.5 3 X 2 X 0.5 4 X 2 X 0.5 7 X 2 X 0.5 2 X 2 X 0.75 3 X 2 X 0.75 4 X 2 X 0.75 7 X 2 X 0.75 2 X 2 X 1 3 X 2 X 1 4 X 2 X 1 7 X 2 X 1 2 X 2 X 1.5 3 X 2 X 1.5 4 X 2 X 1.5 7 X 2 X 1.5 6 X 2 X 0.5 40.1 40.1 40.1 40.1 26.7 26.7 26.7 26.7 20.0 20.0 20.0 20.0 13.7 13.7 13.7 13.7 40.1 84 100 125 180 105 125 155 235 120 145 180 270 170 210 255 415 160 19 X 0.18 19 X 0.18 19 X 0.18 19 X 0.18 37 X 0.16 37 X 0.16 37 X 0.16 37 X 0.16 37 X 0.18 37 X 0.18 37 X 0.18 37 X 0.18 37 X 0.23 37 X 0.23 37 X 0.23 37 X 0.23 19 X 0.18 1.0 1.0 1.0 1.0 1.0 1.0 1.0 1.0 1.0 1.0 1.0 1.0 1.0 1.0 1.0 1.0 1.0 Conductor Construction No.of Strands x Strand dia. (Nos x mm) Max. Conductor 0 Resistance at 20 C ( Ω /km) (Min) (Max) 7.1 7.5 8.3 9.6 7.6 8.2 9.5 11.4 8.3 8.8 9.6 11.6 10.3 11.0 12.1 14.5 10.4 8.9 9.1 9.7 11.6 10.0 10.2 10.8 12.8 10.5 10.7 11.3 13.4 12.2 12.4 13.1 16.3 11.2 Nom. Thickness of Overall Sheath (mm) *Note: C205 6P is not a Standard size as per EN 50306-4 ü Conductor : Finely Stranded Annealed Electro Tinned Copper, (Unilay * ) ü Insulation : Cross Linked Ethylene Copolymer ü Pair : Cores twisted ü General Screen : i) Tinned Copper Braid ii) Wire dia ≥ 0.10 mm iii) Filling Factor ≥ 0.55 ü Separator Tape ü Outersheath : EBXL - EM 104 Black colour or as per customer order. ü For mechanically exposed installation in Rail / Bus and other transport vehicles. ü Cables are used in Driver desks, Control panels, wiring harness in inside/outside the moving vehicles. No. of cores x Cross Section 2 (Nos) x (mm ) IATF 16949 AS 9100 ISO 45001 ISO 9001 ISO 14001 RDSO

RkJQdWJsaXNoZXIy NDgyMjA=