Rolling stock cable

Application Product Construction Technical Data ü Conductor : Finely Stranded Annealed Electro Tinned Copper, (Unilay * ) ü Insulation : Cross Linked Ethylene Copolymer ü Pair : Cores twisted ü General Screen : i) Tinned Copper Braid ii) Wire dia ≥ 0.10 mm iii) Filling Factor ≥ 0.55 ü Separator Tape ü Outersheath : EBXL - EM 104 Black colour or as per customer order. 0 0 ü Temperature Range : -40 C to +90 C. ü Rated Voltage : 300V AC 450V DC ü Specification : BS EN 50306-4 : 2020, Table 7, Class P ü Hazard Level Classification as per EN 45545-2, HL3 Screened and Sheathed Pairs : EN 50306-3 : 2020 Conductor : BS EN 50306-2 : 2020 In addition to BS EN 50306 spec, cables also meet fire performance tests as per UNI CEI 11170-3 DIN 5510-2 NF F 16-101 CEN /TS 45545 0 Siechem BS EN 50306-4 7P Multi Pair, Screened, 300V AC, 450V DC, EBXL 90 C Rolling Stock Cable Part Number Cable Weight (Kg/Km) approx. Outer Diameter (mm) Nom. Thickness of Overall Sheath (mm) ü For mechanically protected installation in Rail / Bus and other transport vehicles. ü Cables are used in Driver desks, Control panels, wiring harness in inside/outside the moving vehicles. 2D View Features ü Excellent resistance to high and low temperature ü Outstanding Flame retardant ü Halogen free ü Thin walled with excellent flexibility ü Resistance to oil, fuel, ozone and weathering. ü Easy to strip ü Low smoke density ü Soldering iron resistant ü Electron Beam Cross Linked. ü Resistance to corona effect. Wires & Cables Catalogue No. RA537 www.siechem.com All information given are in good faith.Siechem's liability is only to replace the defective portion of cables provided the same is mutually established as manufacturing defects within the guarantee period as agreed in writing and Siechem shall not be liable for any compensation or damages. Siechem reserves the right to revise any of the above specifications without prior intimation. Subject to Chennai Jurisdiction. 21 RA5370602P RA5370603P RA5370604P RA5370607P RA5370802P RA5370803P RA5370804P RA5370807P RA5371002P RA5371003P RA5371004P RA5371007P RA5371302P RA5371303P RA5371304P RA5371307P B7460605P B7460606P B7460806P 2 X 2 X 0.5 3 X 2 X 0.5 4 X 2 X 0.5 7 X 2 X 0.5 2 X 2 X 0.75 3 X 2 X 0.75 4 X 2 X 0.75 7 X 2 X 0.75 2 X 2 X 1 3 X 2 X 1 4 X 2 X 1 7 X 2 X 1 2 X 2 X 1.5 3 X 2 X 1.5 4 X 2 X 1.5 7 X 2 X 1.5 5 X 2 X 0.5 6 X 2 X 0.5 6 X 2 X 0.75 0.56 0.56 0.56 0.56 0.56 0.56 0.56 0.56 0.56 0.56 0.56 0.56 0.56 0.56 0.56 0.56 0.56 0.56 0.56 19 X 0.18 19 X 0.18 19 X 0.18 19 X 0.18 37 X 0.16 37 X 0.16 37 X 0.16 37 X 0.16 37 X 0.18 37 X 0.18 37 X 0.18 37 X 0.18 37 X 0.23 37 X 0.23 37 X 0.23 37 X 0.23 19 X 0.18 19 X 0.18 37 X 0.16 40.1 40.1 40.1 40.1 26.7 26.7 26.7 26.7 20.0 20.0 20.0 20.0 13.7 13.7 13.7 13.7 40.1 40.1 26.7 6.6 7.0 7.7 9.0 7.1 7.7 9.0 10.8 7.8 8.3 9.1 11.0 9.8 10.4 11.6 14.0 8.3 9.0 10.8 67 85 100 145 85 105 140 215 105 130 160 250 140 185 235 375 115 130 200 Conductor Construction No.of Strands x Strand dia. (Nos x mm) Max. Conductor 0 Resistance at 20 C ( Ω /km) Siechem EN 50306-4 7P 300 V 2 x 2 x 0.5 MM S 90 (Min) (Max) 7.9 8.1 8.7 10.6 9.0 9.2 10.0 11.8 9.5 9.7 10.3 12.4 11.2 11.4 12.6 15.3 9.5 10.6 11.8 *Note : B746 - 5P,6P is not a standard Size as per EN 50306-4 No. of cores x Cross Section 2 (Nos) x (mm ) IATF 16949 AS 9100 ISO 45001 ISO 9001 ISO 14001 RDSO

RkJQdWJsaXNoZXIy NDgyMjA=