IS 7098 Power Cable

Wires & Cables Area Cond.Min. No.of Wires Thickness of EBXL / XLPE Insulation (Nom.) Approx Overall diameter Approx.Net Wt.of Cable Max.D.C Resistance at 20 deg.C Current Rating For EBXL -XLPE Cables (125°C) Direct in Ground Current Rating For Chemically Cured XLPE Cables (90°C) Short Circuit Rating for 1sec Direct in Ground Thickness of PVC Inner Sheath Dimension of Arm Wire Thickness of Outer Sheath Area Thickness of EBXL / XLPE Insulation (Nom.) A prox.Net Wt.of Cable Max.D.C Re istance at 20 deg.C Current Rating r - les ( ° ) ir t i r In Duct In Air r t ti r i l r l ( ) Short Circuit Rating for 1 sec i i In Duct In Air Sq.mm Nos mm mm Kg/Km Ω/KM Dimension of Arm strips mm mm Cu Cu Cu Cu Cu Cu Cu Product Construction ü Conductor : Annealed Plain copper conductor complying with IS 8130 ü Insulation : Electron Beam Cross Linked Polyethylene 120° C ü Armour : GI Strips ü Jacket : PVC-ST2 (Optional : FRLS, ZHLS) Siechem 4 Core APC Conductor EBXL - XLPE 120°C Insulated GI Strips Armoured PVC ST2 Sheathed 1100 V Power cable as per IS 7098 Application Features Technical Data ü Operating Temperature : -15°C to +120°C High Insulation resistance at elevated temperature ü Short Circuit Temperature : 280°C ü Bending radius (min) : 12 x Cable dia ü Rated Voltage :1100 V ü Test Voltage : 3 kV for 5 mins. ü Specification : IS 7098 Part Number www.siechem.com All information given are in good faith.Siechem's liability is only to replace the defective portion of cables provided the same is mutually established as manufacturing defects within the guarantee period as agreed in writing and Siechem shall not be liable for any compensation or damages. Siechem reserves the right to revise any of the above specifications without prior intimation. Subject to Chennai Jurisdiction. Catalogue No 10 16 25 35 50 70 95 120 150 185 240 300 400 6 6 6 6 6 12 15 18 18 30 34 34 53 0.7 0.7 0.9 0.9 1.0 1.1 1.1 1.2 1.4 1.6 1.7 1.8 2.0 1.4 4 X 0.8 4 X 0.8 4 X 0.8 4 X 0.8 4 X 0.8 4 X 0.8 4 X 0.8 4 X 0.8 4 X 0.8 4 X 0.8 4 X 0.8 4 X 0.8 1.4 1.4 1.4 1.4 1.56 1.56 1.56 1.72 1.88 2.04 2.20 2.36 2.68 20 21 24 26 29 33 36 40 45 50 56 62 68 1030 1070 1532 1982 2507 3459 4462 5560 6768 8264 10373 12940 16981 92 118 151 183 215 267 316 360 407 456 527 593 660 1.83 1.15 0.727 0.524 0.387 0.268 0.193 0.153 0.124 0.0991 0.0754 0.0601 0.0470 74 97 123 149 174 215 255 287 324 362 417 470 523 88 118 151 199 228 291 352 410 472 540 637 735 816 1.4 2.3 3.6 5.0 7.1 10.0 13.6 17.1 21.4 26.4 34.3 42.9 57.1 73 94 120 145 171 212 251 286 323 362 418 471 524 59 77 98 118 138 171 202 228 257 287 331 373 415 68 91 116 153 175 224 271 315 363 415 490 565 628 ü Transmission and distribution of Power Industrial units ü Commercial and residential places ü Indoor and outdoor uses ü Cable ducts, cable trays conduits Direct burial and underground burial where mechanical damage risk for cables. 40 ü Electron Beam Cross Linked. ü Enhanced Mechanical, Electrical, Thermal & Weathering properties. ü Soldering iron resistant ü Resistance to corona effect. ü Easy jointing & termination ü Better resistance to most chemicals & acids ü Low direct electric losses. ü High current carrying capacity. 244WF2704 244WF2804 244WF3004 244WF3204 244WF3404 244WF3704 244WF3804 244WF4104 244WF4204 244WF4404 244WF4604 244WF4804 244WF4904 244W Siechem 4 CoreAPC Conductor EBXL - XLPE 120°C Insulated GI StripsArmoured PVC ST2 Sheathed 1100 V Power cable as per IS 7098 Note : * Cable conforming to IEC 60502 & also available according to customer requirement. * For XLPE 90°C Insulation : 216WF No.of Wires (Min.) Thicknes of Outer Sheath (Min.) CM/L-6819184 IS : 7098 (Pt.1) AS 9100 ISO 45001 ISO 9001 ISO 14001

RkJQdWJsaXNoZXIy NDgyMjA=