IS 7098 Power Cable
Wires & Cables Area Cond.Min. No.of Wires Thickness of EBXL / XLPE Insulation (Nom.) Approx Overall diameter Approx.Net Wt.of Cable Max.D.C Resistance at 20 deg.C Current Rating For EBXL -XLPE Cables (125°C) Direct in Ground Current Rating For Chemically Cured XLPE Cables (90°C) Short Circuit Rating for 1sec Direct in Ground Thickness of PVC Inner Sheath Dimension of Arm Wire Thickness of Outer Sheath Area Thickness of EBXL / XLPE Insulation (Nom.) Approx Overall diamet r l Direct in Ground In Duct In Air u rent Rating For Che ica ly Cured L Cables (90° ) Short Circuit Rating for 1 sec In Duct In Air Sq.mm Nos mm mm Kg/Km Ω/KM Dimension of Arm strips mm mm Cu Cu Cu Cu Cu Cu Cu Product Construction ü Conductor : Annealed Plain copper conductor complying with IS 8130 ü Insulation : Electron Beam Cross Linked Polyethylene 120°C ü Armour : GI Strips ü Jacket : PVC-ST2 (Optional : FRLS, ZHLS) Siechem 3 Core APC Conductor EBXL - XLPE 120°C Insulated GI Strips Armoured PVC ST2 Sheathed 1100 V Power cable as per IS 7098 Application Features Technical Data ü Operating Temperature : -15°C to +120°C High Insulation resistance at elevated temperature ü Short Circuit Temperature : 280°C ü Bending radius (min) : 12 x Cable dia ü Rated Voltage :1100 V ü Test Voltage : 3 kV for 5 mins. ü Specification : IS 7098 www.siechem.com All information given are in good faith.Siechem's liability is only to replace the defective portion of cables provided the same is mutually established as manufacturing defects within the guarantee period as agreed in writing and Siechem shall not be liable for any compensation or damages. Siechem reserves the right to revise any of the above specifications without prior intimation. Subject to Chennai Jurisdiction. Catalogue No Part Number 1.4 4 X 0.8 4 X 0.8 4 X 0.8 4 X 0.8 4 X 0.8 4 X 0.8 4 X 0.8 4 X 0.8 4 X 0.8 4 X 0.8 4 X 0.8 4 X 0.8 10 16 25 35 50 70 95 120 150 185 240 300 400 1.83 1.15 0.727 0.524 0.387 0.268 0.193 0.153 0.124 0.0991 0.0754 0.0601 0.0470 1.4 2.3 3.6 5.0 7.1 10.0 13.6 17.1 21.4 26.4 34.3 42.9 57.1 92 118 151 183 215 267 316 360 407 456 527 593 660 74 97 123 149 174 215 255 287 324 362 417 470 523 88 118 151 199 228 291 352 410 472 540 637 735 816 73 94 120 145 171 212 251 286 323 362 418 471 524 59 77 98 118 138 171 202 228 257 287 331 373 415 68 91 116 153 175 224 271 315 363 415 490 565 628 ü Transmission and distribution of Power Industrial units ü Commercial and residential places ü Indoor and outdoor uses ü Cable ducts, cable trays conduits Direct burial and underground burial where mechanical damage risk for cables. 37 ü Electron Beam Cross Linked. ü Enhanced Mechanical, Electrical, Thermal & Weathering properties. ü Soldering iron resistant ü Resistance to corona effect. ü Easy jointing & termination ü Better resistance to most chemicals & acids ü Low direct electric losses. ü High current carrying capacity. 6 6 6 6 6 12 15 18 18 30 34 34 53 0.7 0.7 0.9 0.9 1.0 1.1 1.1 1.2 1.4 1.6 1.7 1.8 2.0 1.24 1.4 1.4 1.4 1.4 1.56 1.56 1.56 1.72 1.88 2.04 2.20 2.52 19 19 21 23 26 30 33 36 40 45 50 53 58 864 850 1245 1581 1949 2696 3468 4227 5209 6331 7933 9950 12836 244WF2703 244WF2803 244WF3003 244WF3203 244WF3403 244WF3703 244WF3803 244WF4103 244WF4203 244WF4403 244WF4603 244WF4803 244WF4903 244W Siechem 3 CoreAPC Conductor EBXL - XLPE 120°C Insulated GI StripsArmoured PVC ST2 Sheathed 1100 V Power cable as per IS 7098 Note : * Cable conforming to IEC 60502 & also available according to customer requirement. * For XLPE 90°C Insulation : 216WF No.of Wires (Min.) Thickness of Outer Sheath (Min.) CM/L-6819184 IS : 7098 (Pt.1) AS 9100 ISO 45001 ISO 9001 ISO 14001
Made with FlippingBook
RkJQdWJsaXNoZXIy NDgyMjA=