IS 7098 Power Cable
Wires & Cables Area Cond.Min. No.of Wires Thickness of EBXL / XLPE Insulation (Nom.) Approx Overall diameter Approx.Net Wt.of Cable Max.D.C Resistance at 20 deg.C Current Rating For EBXL -XLPE Cables (125°C) Direct in Ground Current Rating For Chemically Cured XLPE Cables (90°C) Short Circuit Rating for 1sec Direct in Ground Thickness of PVC Inner Sheath Dimension of Arm Wire Thickness of Outer Sheath Area Thickness of EBXL / XLPE Insulation (Nom.) Approx Overall diameter Approx.Net Wt.of Cable Max.D.C Re istance at 20 deg.C i l irect in round In Duct In Air u rent Rating For Che ica ly Cured L Cables (90° ) Short Circuit Rating for 1 sec i t i In Duct In Air Sq.mm Nos mm mm Kg/Km Ω/KM Dimension of Arm st ips mm mm Cu Cu Cu Cu Cu Cu Cu Product Construction ü Conductor : Annealed Plain copper conductor complying with IS 8130 ü Insulation : Electron Beam Cross Linked Polyethylene 120°C ü Armour : GI Strips ü Jacket : PVC-ST2 (Optional : FRLS, ZHLS) Siechem 2 Core APC Conductor EBXL - XLPE 120°C Insulated GI Strips Armoured PVC ST2 Sheathed 1100 V Power cable as per IS 7098 Application Features Technical Data ü Operating Temperature : -15°C to +120°C High Insulation resistance at elevated temperature ü Short Circuit Temperature : 280°C ü Bending radius (min) : 12 x Cable dia ü Rated Voltage :1100 V ü Test Voltage : 3 kV for 5 mins. ü Specification : IS 7098 www.siechem.com All information given are in good faith.Siechem's liability is only to replace the defective portion of cables provided the same is mutually established as manufacturing defects within the guarantee period as agreed in writing and Siechem shall not be liable for any compensation or damages. Siechem reserves the right to revise any of the above specifications without prior intimation. Subject to Chennai Jurisdiction. Catalogue No Part Number 10 16 25 35 50 70 95 120 150 185 240 300 400 1.4 2.3 3.6 5.0 7.1 10.0 13.6 17.1 21.4 26.4 34.3 42.9 57.1 1.83 1.15 0.727 0.524 0.387 0.268 0.193 0.153 0.124 0.9991 0.0754 0.0601 0.0470 110 142 181 219 260 320 378 431 486 544 629 711 834 92 117 150 179 212 262 307 349 394 442 509 575 668 101 137 177 218 267 342 416 485 559 641 758 876 974 87 113 144 174 206 254 300 342 386 432 499 564 622 73 93 119 142 168 208 244 277 313 351 404 456 530 78 105 136 168 205 263 320 373 430 493 583 674 749 1.4 4 X 0.8 4 X 0.8 4 X 0.8 4 X 0.8 4 X 0.8 4 X 0.8 4 X 0.8 4 X 0.8 4 X 0.8 4 X 0.8 4 X 0.8 4 X 0.8 ü Transmission and distribution of Power Industrial units ü Commercial and residential places ü Indoor and outdoor uses ü Cable ducts, cable trays conduits Direct burial and underground burial where mechanical damage risk for cables. 35 ü Electron Beam Cross Linked. ü Enhanced Mechanical, Electrical, Thermal & Weathering properties. ü Soldering iron resistant ü Resistance to corona effect. ü Easy jointing & termination ü Better resistance to most chemicals & acids ü Low direct electric losses. ü High current carrying capacity. 6 6 6 6 6 12 15 18 18 30 34 34 53 0.7 0.7 0.9 0.9 1.0 1.1 1.1 1.2 1.4 1.6 1.7 1.8 2.0 1.24 1.24 1.4 1.4 1.4 1.56 1.56 1.56 1.72 1.72 1.72 1.88 2.04 17.0 18.0 19.0 21.0 23.0 26.0 29.0 31.0 35.0 38.0 41.0 47.0 52.0 760 790 950 1085 1460 1950 2500 3050 3650 4440 5486 6990 9030 Siechem 2 CoreAPC Conductor EBXL - XLPE 120°C Insulated GI StripsArmoured PVC ST2 Sheathed 1100 V Power cable as per IS 7098 244WF2702 244ER2802 244WF3002 244WF3202 244WF3402 244WF3702 244WF3802 244WF4102 244WF4202 244WF4402 244WF4602 244WF4802 244WF4902 244W Note : * Cable conforming to IEC 60502 & also available according to customer requirement. * For XLPE 90°C Insulation : 216WF . No.of Wires (Min.) Thickness of Outer Sh ath (Min.) CM/L-6819184 IS : 7098 (Pt.1) AS 9100 ISO 45001 ISO 9001 ISO 14001
Made with FlippingBook
RkJQdWJsaXNoZXIy NDgyMjA=