IS 7098 Power Cable

Wires & Cables Area Thickness of EBXL / XLPE Insulation (Nom.) Approx Overall diameter Approx.Net Wt.of Cable Max.D.C Resistance at 20 deg.C Current Rating For EBXL -XLPE Cables (125°C) Direct in Ground In Duct In Air Current Rating For Chemically Cured XLPE Cables (90°C) Short Circuit Rating for 1 sec Direct in Ground In Duct In Air Sq.mm Cu Cu Cu Cu Cu Cu Cu Sq.mm Nos mm Nos mm mm Kg/Km Ω/KM Main Neutral Main Neutral Neutral Product Construction ü Conductor : Annealed Plain copper conductor complying with IS 8130 ü Insulation : Electron Beam Cross Linked Polyethylene 120°C ü Jacket : PVC-ST2 (Optional : FRLS, ZHLS) Siechem 3.5 Core APC Conductor EBXL - XLPE 120°C Insulated PVC ST2 Sheathed 600/1000 V (UA) Power cable as per IS 7098 Application Features Technical Data ü Operating Temperature : -15°C to +120°C High Insulation resistance at elevated temperature ü Short Circuit Temperature : 280°C ü Bending radius (min) : 12 x Cable dia ü Rated Voltage :1100 V ü Test Voltage : 3 kV for 5 mins. ü Specification : IS 7098 www.siechem.com All information given are in good faith.Siechem's liability is only to replace the defective portion of cables provided the same is mutually established as manufacturing defects within the guarantee period as agreed in writing and Siechem shall not be liable for any compensation or damages. Siechem reserves the right to revise any of the above specifications without prior intimation. Subject to Chennai Jurisdiction. Catalogue No Part Number mm Main 25 35 50 70 95 120 150 185 240 300 400 16 16 25 35 50 70 70 95 120 150 185 6 6 6 12 15 15 15 30 30 30 53 6 6 6 6 6 12 12 15 15 15 30 0.9 0.9 1.0 1.1 1.1 1.2 1.4 1.6 1.7 1.8 2.0 0.7 0.7 0.9 0.9 1.0 1.1 1.1 1.1 1.2 1.4 1.6 0.727 0.524 0.387 0.268 0.193 0.153 0.124 0.0991 0.0754 0.0601 0.0470 151 183 215 267 316 360 407 456 527 593 660 123 149 174 215 255 287 324 362 417 470 523 151 199 228 291 352 410 472 540 637 735 816 98 118 138 171 202 228 257 287 331 373 415 116 153 175 224 271 315 363 415 490 565 628 3.6 5.0 7.1 10.0 13.6 17.1 21.4 26.4 34.3 42.9 57.1 120 145 171 212 251 286 323 362 418 471 524 ü Transmission and distribution of Power Industrial units ü Commercial and residential places ü Indoor and outdoor uses ü Cable ducts, cable trays conduits Direct burial and underground burial where mechanical damage risk for cables. 30 ü Electron Beam Cross Linked. ü Enhanced Mechanical, Electrical, Thermal & Weathering properties. ü Soldering iron resistant ü Resistance to corona effect. ü Easy jointing & termination ü Better resistance to most chemicals & acids ü Low direct electric losses. ü High current carrying capacity. 2.0 2.0 2.0 2.2 2.2 2.2 2.4 2.6 2.8 3.0 3.4 22.0 24..0 27.0 32.0 35.0 38.0 42.0 47.0 54.0 57.0 65.0 1033 1410 1848 2629 3416 4330 5290 6595 8448 10347 13930 Siechem 3.5 CoreAPC Conductor EBXL - XLPE 120°C Insulated PVC ST2 Sheathed 1100 V (UA) Power cable as per IS 7098 240E303H 240E323H 240E343H 240E373H 240E383H 240E413H 240E423H 240E443H 240E463H 240E483H 240E493H 240E Note : * Cable conforming to IEC 60502 & also available according to customer requirement. * For XLPE 90°C Insulation : 212E No.of Wires (Min.) Thickness of Outer Sheath (Nom.) CM/L-6819184 IS : 7098 (Pt.1) AS 9100 ISO 45001 ISO 9001 ISO 14001

RkJQdWJsaXNoZXIy NDgyMjA=