IS 7098 Power Cable
Wires & Cables Area Thickness of EBXL / XLPE Insulation (Nom.) Approx Overall diameter Approx.Net Wt.of Cable Max.D.C Resistance at 20 deg.C Current Rating For EBXL -XLPE Cables (125°C) Direct in Ground In Duct In Air Current Rating For Chemically Cured XLPE Cables (90°C) Short Circuit Rating for 1 sec Direct in Ground In Duct In Air Sq.mm Nos mm mm Kg/Km Ω/KM Cu Cu Cu Cu Cu Cu Cu mm Product Construction ü Conductor : Annealed Plain copper conductor complying with IS 8130 ü Insulation : Electron Beam Cross Linked Polyethylene 120°C ü Jacket : PVC-ST2 (Optional : FRLS, ZHLS) Siechem 3 Core APC Conductor EBXL - XLPE 120°C Insulated PVC ST2 Sheathed 1100 V (UA) Power cable as per IS 7098 Application Features Technical Data ü Operating Temperature : -15°C to +120°C High Insulation resistance at elevated temperature ü Short Circuit Temperature : 280°C ü Bending radius (min) : 12 x Cable dia ü Rated Voltage :1100 V ü Test Voltage : 3 kV for 5 mins. ü Specification : IS 7098 www.siechem.com All information given are in good faith.Siechem's liability is only to replace the defective portion of cables provided the same is mutually established as manufacturing defects within the guarantee period as agreed in writing and Siechem shall not be liable for any compensation or damages. Siechem reserves the right to revise any of the above specifications without prior intimation. Subject to Chennai Jurisdiction. Catalogue No Part Number 10 16 25 35 50 70 95 120 150 185 240 300 400 6 6 6 6 6 12 15 18 18 30 34 34 53 0.7 0.7 0.9 0.9 1.0 1.1 1.1 1.2 1.4 1.6 1.7 1.8 2.0 1.8 1.8 2.0 2.0 2.0 2.2 2.2 2.2 2.2 2.6 2.8 3.0 3.2 17 18 20 22 25 29 32 35 39 44 49 52 57 1.83 1.15 0.727 0.524 0.387 0.268 0.193 0.153 0.124 0.0991 0.0754 0.0601 0.0470 1.4 2.3 3.6 5.0 7.1 10.0 13.6 17.1 21.4 26.4 34.3 42.9 57.1 59 77 98 118 138 171 202 228 257 287 331 373 415 68 91 116 153 175 224 271 315 363 415 490 565 628 73 94 120 145 171 212 251 286 323 362 418 471 524 88 118 151 199 228 291 352 410 472 540 637 735 816 74 97 123 149 174 215 255 287 324 362 417 470 523 92 118 151 183 215 267 316 360 407 456 527 593 660 ü Transmission and distribution of Power Industrial units ü Commercial and residential places ü Indoor and outdoor uses ü Cable ducts, cable trays conduits Direct burial and underground burial where mechanical damage risk for cables. 29 ü Electron Beam Cross Linked. ü Enhanced Mechanical, Electrical, Thermal & Weathering properties. ü Soldering iron resistant ü Resistance to corona effect. ü Easy jointing & termination ü Better resistance to most chemicals & acids ü Low direct electric losses. ü High current carrying capacity. 450 553 865 1161 1560 2200 2940 3650 4600 5760 7340 9100 12100 Siechem 3 Core APC Conductor EBXL - XLPE 120°C Insulated PVC ST2 Sheathed 1100 V (UA) Power cable as per IS 7098 240E2703 240E2803 240E3003 240E3203 240E3403 240E3703 240E3803 240E4103 240E4203 240E4403 240E4603 240E4803 240E4903 240E Note : * Cable conforming to IEC 60502 & also available according to customer requirement. * For XLPE 90°C Insulation : 212E No.of Wires (Min.) Thickness of Outer Sheath (Nom.) CM/L-6819184 IS : 7098 (Pt.1) AS 9100 ISO 45001 ISO 9001 ISO 14001
Made with FlippingBook
RkJQdWJsaXNoZXIy NDgyMjA=