IS 7098 Power Cable

Wires & Cables Product Construction Technical Data Area No.of Wires (Min.) Thickness of EBXL- XLPE Insulation (Nom.) Thickness of Outer Sheath (Nom.) Approx Overall diameter Approx.Net Wt.of Cable Max.D.C Resistance at 20 deg.C Current Rating For EBXL-XLPE Cables (125°C) Direct in Ground In Duct In Air Current Rating For Chemically Cured XLPE Cables (90°C) Short Circuit Rating for 1sec Direct in Ground In Duct In Air Sq.mm Nos mm mm mm Kg/Km Ω/KM Cu Cu Cu Cu Cu Cu Cu www.siechem.com All information given are in good faith.Siechem's liability is only to replace the defective portion of cables provided the same is mutually established as manufacturing defects within the guarantee period as agreed in writing and Siechem shall not be liable for any compensation or damages. Siechem reserves the right to revise any of the above specifications without prior intimation. Subject to Chennai Jurisdiction. Catalogue No Part Number ü Conductor : Annealed Plain Copper conductor complying with IS 8130 ü Insulation : Electron Beam Cross Linked Polyethylene 120°C ü Jacket : PVC ST2 (Optional : FRLS, ZHLS) Siechem Single Core APC Conductor EBXL - XLPE 120°C Insulated PVC ST2 Sheathed 1100 V (UA) Power cable as per IS 7098 Application Features ü Electron Beam Cross Linked. ü Enhanced Mechanical, Electrical, Thermal & Weathering properties. ü Soldering iron resistant ü Resistance to corona effect. ü Easy jointing & termination ü Better resistance to most chemicals & acids ü Low direct electric losses. ü High current carrying capacity. ü Operating Temperature : -15°C to +120°C High Insulation resistance at elevated temperature ü Short Circuit Temperature : 280°C ü Bending radius (min) : 12 x Cable dia ü Rated Voltage :1100 V ü Test Voltage : 3 kV for 5 mins. ü Specification : IS 7098 ü Transmission and distribution of Power Industrial units ü Commercial and residential places ü Indoor and outdoor uses ü Cable ducts, cable trays conduits Direct burial and underground burial where mechanical damage risk for cables. 25 1.5 2.5 4 6 10 16 25 35 50 70 95 120 150 185 240 300 400 500 630 1 1 1 1 6 6 6 6 6 12 15 18 18 30 34 34 53 53 53 0.7 0.7 0.7 0.7 0.7 0.7 0.9 0.9 1.0 1.1 1.1 1.2 1.4 1.6 1.7 1.8 2.0 2.2 2.4 1.8 1.8 1.8 1.8 1.8 1.8 1.8 1.8 1.8 1.8 1.8 1.8 2.0 2.0 2.0 2.0 2.2 2.2 2.2 6.8 7.2 7.5 8.0 9.0 10.0 11.5 12.5 13.5 15.5 17.0 19.0 21.0 23.0 26.0 28.0 33.0 36.0 40.0 65 75 95 120 165 225 320 415 545 770 1000 1260 1570 1910 2410 2980 3970 4945 6130 12.1 7.41 4.61 3.08 1.83 1.15 0.727 0.524 0.387 0.268 0.193 0.153 0.124 0.9991 0.0754 0.0601 0.0470 0.0366 0.0283 39 53 68 86 112 150 192 229 272 333 396 449 507 571 665 750 838 941 1065 34 45 60 74 98 126 164 197 234 290 344 398 447 513 600 688 786 895 1037 34 47 61 78 105 140 191 237 286 367 446 517 597 680 803 927 1112 1282 1483 31 42 54 68 89 119 152 182 216 264 314 356 402 453 528 595 665 747 845 27 36 48 59 78 100 130 156 186 230 273 316 355 407 476 546 624 710 823 26 36 47 60 81 108 147 182 220 282 343 398 459 523 618 713 855 986 1141 0.21 0.36 0.57 0.86 1.4 2.3 3.6 5.0 7.1 10.0 13.6 17.1 21.4 26.4 34.3 42.9 57.1 71.4 90.0 239SE13XX 239SE16XX 239SE19XX 239SE23XX 240SE17XX 240SE28XX 240SE30XX 240SE32XX 240SE34XX 240SE37XX 240SE38XX 240SE41XX 240SE42XX 240SE44XX 240SE46XX 240SE48XX 240SE49XX 240SE50XX 240SE51XX 240SE Siechem Single Core APC Conductor EBXL - XLPE 120°C Insulated PVC ST2 Sheathed 1100 V (UA) Power cable as per IS 7098 Note : * Cable conforming to IEC 60502 & also available according to customer requirement. * For XLPE 90°C Insulation from 4 to 10 sqmm - 211SE from 16 to 630 sqmm- 212SE CM/L-6819184 IS : 7098 (Pt.1) AS 9100 ISO 45001 ISO 9001 ISO 14001

RkJQdWJsaXNoZXIy NDgyMjA=