IS 7098 Power Cable
Wires & Cables Area Thickness of EBXL / XLPE Insulation (Nom.) Approx Overall diameter Approx.Net Wt.of Cable Max.D.C Resistance at 20 deg.C Current Rating For EBXL -XLPE Cables (125°C) Direct in Ground In Duct In Air Current Rating For Chemically Cured XLPE Cables (90°C) Short Circuit Rating for 1sec Direct in Ground In Duct In Air Sq.mm Nos mm mm Kg/Km Ω/KM Dimension of Arm GI Strips mm mm ü Conductor : Aluminium conductor complying with IS 8130 ü Insulation : Electron Beam Cross Linked Polyethylene 120°C ü Armour : GI strips ü Jacket : PVC-ST2 (Optional : FRLS, ZHLS) Part Number Product Construction 0 Siechem 2 Core Aluminium Conductor EBXL - XLPE 120 C Insulated GI Strip Armoured PVC ST2 Sheathed 1100 V Power cable as per IS 7098 Technical Data 16 25 35 50 70 95 120 150 185 240 300 400 6 6 6 6 12 15 15 15 30 30 30 53 0.7 0.9 0.9 1.0 1.1 1.1 1.2 1.4 1.6 1.7 1.8 2.0 1.91 1.20 0.868 0.641 0.443 0.320 0.253 0.206 0.164 0.125 0.100 0.0778 1.5 2.4 3.3 4.7 6.6 9.0 11.3 14.2 17.5 22.6 28.3 37.7 ü Operating Temperature : -15°C to +120°C High Insulation resistance at elevated temperature ü Short Circuit Temperature : 280°C ü Bending radius (min) : 12 x Cable dia ü Rated Voltage :1100 V ü Test Voltage : 3 kV for 5 mins. ü Specification : IS 7098 Application Features ü Transmission and distribution of Power Industrial units ü Commercial and residential places ü Indoor and outdoor uses ü Cable ducts, cable trays conduits Direct burial and underground burial where mechanical damage risk for cables. Al Al Al Al Al Al Al ü Electron Beam Cross Linked. ü Enhanced Mechanical, Electrical, Thermal & Weathering properties. ü Soldering iron resistant ü Resistance to corona effect. ü Easy jointing & termination ü Better resistance to most chemicals & acids ü Low direct electric losses. ü High current carrying capacity. 4X0.8 4X0.8 4X0.8 4X0.8 4X0.8 4X0.8 4X0.8 4X0.8 4X0.8 4X0.8 4X0.8 4X0.8 1.4 1.4 1.4 1.4 1.56 1.56 1.56 1.72 1.72 1.88 2.04 2.36 18.0 19.0 21.0 23.0 26.0 29.0 31.0 35.0 38.0 41.0 47.0 52.0 605 630 730 860 1070 1330 1540 1800 2240 2630 3260 4060 Siechem 2 CoreAluminium Conductor EBXL - XLPE 120°C Insulated GI StripArmoured PVC ST2 Sheathed 1100 V Power cable as per IS 7098 234ER2802 234WF3002 234WF3202 234WF3402 234WF3702 234WF3802 234WF4102 234WF4202 234WF4402 234WF4602 234WF4802 234WF4902 Catalogue No www.siechem.com 234E 19 All information given are in good faith.Siechem's liability is only to replace the defective portion of cables provided the same is mutually established as manufacturing defects within the guarantee period as agreed in writing and Siechem shall not be liable for any compensation or damages. Siechem reserves the right to revise any of the above specifications without prior intimation. Subject to Chennai Jurisdiction. Note : * Cable conforming to IEC 60502 & also available according to customer requirement. * For XLPE 90°C from 16 to 630 sqmm- 206WF . No.of Wires (Min.) 110 140 168 198 244 290 330 373 418 483 546 606 92 116 139 165 204 239 272 306 344 396 446 495 108 127 160 194 250 304 355 410 469 556 642 714 87 111 133 157 194 230 262 296 332 383 433 481 73 92 110 131 162 190 216 243 273 314 354 393 83 98 123 149 192 234 273 315 361 428 494 549 Thickness of Outer Sheath (min) CM/L-6819184 IS : 7098 (Pt.1) AS 9100 ISO 45001 ISO 9001 ISO 14001
Made with FlippingBook
RkJQdWJsaXNoZXIy NDgyMjA=