IS 7098 Power Cable

Wires & Cables Area Thickness of EBXL / XLPE Insulation (Nom.) Approx Overall diameter Approx.Net Wt.of Cable Max.D.C Resistance at 20 deg.C Current Rating For EBXL -XLPE Cables (125°C) Direct in Ground In Duct In Air Current Rating For Chemically Cured XLPE Cables (90°C) Short Circuit Rating for 1sec Direct in Ground In Duct In Air Sq.mm Nos mm mm Kg/Km Ω/KM Dimension of Arm Wire mm mm ü Conductor : Aluminium conductor complying with IS 8130 ü Insulation : Electron Beam Cross Linked Polyethylene 120°C ü Armour : GI wire ü Jacket : PVC-ST2 (Optional : FRLS, ZHLS) Part Number Product Construction Siechem 2 Core Round Aluminium Conductor EBXL - XLPE 120°C Insulated GI wire Armoured PVC ST2 Sheathed 1100 V Power cable as per IS 7098 Technical Data 4 6 10 7.41 4.61 3.08 0.38 0.57 0.94 ü Operating Temperature : -15°C to +120°C High Insulation resistance at elevated temperature ü Short Circuit Temperature : 280°C ü Bending radius (min) : 12 x Cable dia ü Rated Voltage :1100 V ü Test Voltage : 3 kV for 5 mins. ü Specification : IS 7098 Application Features ü Transmission and distribution of Power Industrial units ü Commercial and residential places ü Indoor and outdoor uses ü Cable ducts, cable trays conduits Direct burial and underground burial where mechanical damage risk for cables. Al Al Al Al Al Al Al ü Electron Beam Cross Linked. ü Enhanced Mechanical, Electrical, Thermal & Weathering properties. ü Soldering iron resistant ü Resistance to corona effect. ü Easy jointing & termination ü Better resistance to most chemicals & acids ü Low direct electric losses. ü High current carrying capacity. 1 1 1 0.7 0.7 0.7 1.4 1.4 1.4 1.24 1.24 1.24 15.0 16.0 17.0 440 500 600 Siechem2CoreRoundAluminiumConductorEBXL -XLPE 120°C InsulatedGIwireArmouredPVCST2Sheathed 1100VPower cable asper IS 7098 233ER1902 233ER2302 233ER2702 Catalogue No www.siechem.com 233E 18 All information given are in good faith.Siechem's liability is only to replace the defective portion of cables provided the same is mutually established as manufacturing defects within the guarantee period as agreed in writing and Siechem shall not be liable for any compensation or damages. Siechem reserves the right to revise any of the above specifications without prior intimation. Subject to Chennai Jurisdiction. Note : * Cable conforming to IEC 60502 & also available according to customer requirement. * For XLPE 90°C Insulation from 4 to 10 sqmm - 205ER . No.of Wires (Min.) 50 63 84 43 54 71 46 59 79 40 50 67 34 43 56 35 45 61 Thickness of Outer Sheath (min) CM/L-6819184 IS : 7098 (Pt.1) AS 9100 ISO 45001 ISO 9001 ISO 14001

RkJQdWJsaXNoZXIy NDgyMjA=