IS 7098 Power Cable

Wires & Cables Features Area Thickness of EBXL / XLPE Insulation (Nom.) Thickness of Outer Sheath Unarm Approx Overall diameter Approx.Net Wt.of Cable Max.D.C Resistance at 20 deg.C Current Rating For EBXL -XLPE Cables (125°C) Direct in Ground In Duct In Air Current Rating For Chemically Cured XLPE Cables (90°C) Short Circuit Rating for 1sec Direct in Ground In Duct In Air Sq.mm Nos mm mm mm Kg/Km Ω/KM Al ü Operating Temperature : -15°C to +120°C High Insulation resistance at elevated temperature ü Short Circuit Temperature : 280°C ü Bending radius (min) : 12 x Cable dia ü Rated Voltage :1100 V ü Test Voltage : 3 kV for 5 mins. ü Specification : IS 7098 ü Transmission and distribution of Power Industrial units ü Commercial and residential places ü Indoor and outdoor uses ü Cable ducts, cable trays conduits Direct burial and underground burial where mechanical damage risk for cables. ü Electron Beam Cross Linked. ü Enhanced Mechanical, Electrical, Thermal & Weathering properties. ü Soldering iron resistant ü Resistance to corona effect. ü Easy jointing & termination ü Better resistance to most chemicals, oils & acids ü Low direct electric losses. ü High current carrying capacity. ü Conductor : Aluminium conductor complying with IS 8130 ü Insulation : Electron Beam Cross Linked Polyethylene 120°C ü Jacket : PVC-ST2 (Optional : FRLS, ZHLS) Part Number Al Al Al Al Al Al Product Construction Technical Data Application Siechem 2 Core sec Aluminium Conductor EBXL - XLPE 120°C Insulated PVC ST2 Sheathed 1100 V (UA) Power cable as per IS 7098 16 25 35 50 70 95 120 150 185 240 300 400 6 6 6 6 12 15 18 18 30 34 34 53 1.8 0.9 0.9 1.0 1.1 1.1 1.2 1.4 1.6 1.7 1.8 2.0 2.0 2.0 2.0 2.0 2.0 2.2 2.2 2.2 2.4 2.6 2.8 3.0 15.0 18.0 20.0 22.0 24.0 28.0 30.0 33.0 37.0 39.5 45.0 50.0 280 320 390 480 630 820 990 1190 1490 1900 2360 2940 1.91 1.20 0.868 0.641 0.443 0.320 0.253 0.206 0.164 0.125 0.100 0.0778 110 140 168 198 244 290 330 373 418 483 546 606 92 116 139 165 204 239 272 306 344 396 446 495 108 127 160 194 250 304 355 410 469 556 642 714 87 111 133 157 194 230 262 296 332 383 433 481 73 92 110 131 162 190 216 243 273 314 354 393 1.5 2.4 3.3 4.7 6.6 9.0 11.3 14.2 17.5 22.6 28.3 37.7 83 98 123 149 192 234 273 315 361 428 494 549 0 Siechem 2 Core secAluminium Conductor EBXL - XLPE 120 C Insulated PVC ST2 Sheathed 1100 V (UA) Power cable as per IS 7098 230E2802 230E3002 230E3202 230E3402 230E3702 230E3802 230E4102 230E4202 230E4402 230E4602 230E4802 230E4902 Note : * Cable conforming to IEC 60502 & also available according to customer requirement. * For XLPE 90°C Insulation : 202E . Catalogue No www.siechem.com 230E 11 All information given are in good faith.Siechem's liability is only to replace the defective portion of cables provided the same is mutually established as manufacturing defects within the guarantee period as agreed in writing and Siechem shall not be liable for any compensation or damages. Siechem reserves the right to revise any of the above specifications without prior intimation. Subject to Chennai Jurisdiction. No.of Wires (Min.) CM/L-6819184 IS : 7098 (Pt.1) AS 9100 ISO 45001 ISO 9001 ISO 14001

RkJQdWJsaXNoZXIy NDgyMjA=