BS 5467 Power cable
Wires & Cables Area Cond.Min. No.of Wires Thickness of EBXL / XLPE Insulation (Nom.) Thickness of Outer Sheath Approx Overall diameter Approx.Net Wt.of Cable Max.D.C Resistance at 20 deg.C Current Rating For EBXL -XLPE Cables (125°C) Direct in Ground In Duct In Air Current Rating For Chemically Cured XLPE Cables (90°C) Short Circuit Rating for 1 sec Direct in Ground In Duct In Air Sq.mm Cu Cu Cu Cu Cu Cu Cu Sq.mm Nos mm Nos mm mm mm Kg/Km Ω/KM main Neutral main Neutral main Neutral Dimension of Arm strips mm Product Construction ü Conductor : Annealed Plain copper conductor complying with BS 6360 ü Insulation : Electron Beam Cross Linked Polyethylene 120°C ü Armour : GI Strips ü Jacket : PVC Complying with BS 6746 0 Siechem 3.5 Core APC Conductor EBXL - XLPE 120 C Insulated GI Strips Armoured PVC Sheathed 600/1000 V Power cable as per BS 5467 Application Features Technical Data ü Operating Temperature : -15°C to +120°C High Insulation resistance at elevated temperature ü Short Circuit Temperature : 280°C ü Bending radius (min) : 12 x Cable dia ü Rated Voltage :600/1000 V ü Test Voltage : 3.5 kV for 5 mins. ü Specification : BS 5467 Part Number 752E303H 752E323H 752E343H 752E373H 752E383H 752E413H 752E423H 752E443H 752E463H 752E483H 752E493H 25 35 50 70 95 120 150 185 240 300 400 16 16 25 35 50 70 70 95 120 150 185 7 7 7 19 19 19 19 37 37 37 61 7 7 7 7 7 19 19 19 19 19 37 0.9 0.9 1.0 1.1 1.1 1.2 1.4 1.6 1.7 1.8 2.0 0.7 0.7 0.9 0.9 1.0 1.1 1.1 1.1 1.2 1.4 1.6 1.4 1.4 1.4 1.56 1.56 1.72 1.72 1.88 2.04 2.2 2.52 22.9 25.1 28.3 32.4 35.7 39.4 43.6 48.3 53.8 59.1 67.6 1439 1782 2364 3151 4070 5051 6049 7407 9347 11454 14883 0.8 X 4 0.8 X 4 0.8 X 4 0.8 X 4 0.8 X 4 0.8 X 4 0.8 X 4 0.8 X 4 0.8 X 4 0.8 X 4 0.8 X 4 0.727 0.524 0.387 0.268 0.193 0.153 0.124 0.0991 0.0754 0.0601 0.0470 159 190 224 274 329 373 417 469 541 603 677 143 170 202 247 296 335 376 423 486 543 610 143 172 211 257 312 359 413 476 554 624 703 110 131 155 190 228 258 289 325 374 418 469 110 132 162 198 240 276 318 366 426 480 546 3.6 5.0 7.1 10.0 13.6 17.1 21.4 26.4 34.3 42.9 57.1 122 146 172 211 253 287 321 361 416 464 521 ü Transmission and distribution of Power Industrial units ü Commercial and residential places ü Indoor and outdoor uses ü Cable ducts, cable trays conduits Direct burial and underground burial where mechanical damage risk for cables. ü Electron Beam Cross Linked. ü Enhanced Mechanical, Electrical, Thermal & Weathering properties. ü Soldering iron resistant ü Resistance to corona effect. ü Easy jointing & termination ü Better resistance to most chemicals & acids ü Low direct electric losses. ü High current carrying capacity. Siechem 3.5CoreAPCConductorEBXL -XLPE 120°C InsulatedGIStripsArmouredPVCSheathed 600/1000VPower cable asperBS 5467 Cable conforming to IEC 60502 & VDE-0271 also available according to customer requirement. 752E Catalogue No www.siechem.com All information given are in good faith.Siechem's liability is only to replace the defective portion of cables provided the same is mutually established as manufacturing defects within the guarantee period as agreed in writing and Siechem shall not be liable for any compensation or damages. Siechem reserves the right to revise any of the above specifications without prior intimation. Subject to Chennai Jurisdiction. 38 CM/L-6819184 IS : 7098 (Pt.1) AS 9100 ISO 45001 ISO 9001 ISO 14001
Made with FlippingBook
RkJQdWJsaXNoZXIy NDgyMjA=