BS 5467 Power cable
Wires & Cables Area Cond.Min. No.of Wires Thickness of EBXL / XLPE Insulation (Nom.) Approx Overall diameter Approx.Net Wt.of Cable Max.D.C Resistance at 20 deg.C Current Rating For EBXL -XLPE Cables (125°C) Direct in Ground Current Rating For Chemically Cured XLPE Cables (90°C) Short Circuit Rating for 1sec Direct in Ground Thickness of PVC Inner Sheath Dimension of Arm Wire Thickness of Outer Sheath Area Cond.Min. No.of Wires Thickness of EBXL / XLPE I sulation (Nom.) ax.D.C esistance at 20 deg.C r t tin r - les ( ° ) Direct in Ground In Duct In Air t ti i l l Short Circuit Rating for 1 sec Direct in Ground In Duct In Air Sq.mm Nos mm mm Kg/Km Ω/KM Dimension of Arm Wire Thicknes of Outer Sheath mm mm Cu Cu Cu Cu Cu Cu Cu Product Construction ü Conductor : Annealed Plain copper conductor complying with BS 6360 ü Insulation : Electron Beam Cross Linked Polyethylene 120°C ü Armour : GI wire ü Jacket : PVC Complying with BS 6746 Siechem 3 Round Core APC Conductor EBXL - XLPE 120°C Insulated GI wire Armoured PVC Sheathed 600/1000 V Power cable as per BS 5467 Application Features Technical Data ü Operating Temperature : -15°C to +120°C High Insulation resistance at elevated temperature ü Short Circuit Temperature : 280°C ü Bending radius (min) : 12 x Cable dia ü Rated Voltage :600/1000 V ü Test Voltage : 3.5 kV for 5 mins. ü Specification : BS 5467 Part Number 750ER1303 750ER1603 750ER1903 750ER2303 750ER2703 750ER2803 750ER3003 750ER3203 1.5 2.5 4 6 10 16 25 35 1 1 1 1 7 7 7 19 0.6 0.7 0.7 0.7 0.7 0.7 0.9 0.9 0.9 0.9 0.9 0.9 1.25 1.25 1.6 1.6 1.24 1.24 1.24 1.24 1.4 1.4 1.4 1.4 13.3 14.6 15.6 16.7 20.5 20.5 24.8 24.8 335 408 488 583 914 1071 1627 1888 12.1 7.41 4.61 3.08 1.83 1.15 0.727 0.524 33 44 57 72 95 126 159 190 30 40 52 65 86 113 143 170 29 39 52 65 82 117 143 182 25 34 44 55 73 97 122 146 23 31 40 50 66 87 110 131 0.21 0.36 0.57 0.86 1.4 2.3 3.6 5.0 22 30 40 51 63 90 110 140 ü Transmission and distribution of Power Industrial units ü Commercial and residential places ü Indoor and outdoor uses ü Cable ducts, cable trays conduits Direct burial and underground burial where mechanical damage risk for cables. ü Electron Beam Cross Linked. ü Enhanced Mechanical, Electrical, Thermal & Weathering properties. ü Soldering iron resistant ü Resistance to corona effect. ü Easy jointing & termination ü Better resistance to most chemicals & acids ü Low direct electric losses. ü High current carrying capacity. Siechem 3CoreAPCConductorEBXL -XLPE 120°C InsulatedGIwireArmouredPVCSheathed 600/1000VPowercable asperBS 5467 Cable conforming to IEC 60502 & VDE-0271 also available according to customer requirement. 750E Catalogue No www.siechem.com All information given are in good faith.Siechem's liability is only to replace the defective portion of cables provided the same is mutually established as manufacturing defects within the guarantee period as agreed in writing and Siechem shall not be liable for any compensation or damages. Siechem reserves the right to revise any of the above specifications without prior intimation. Subject to Chennai Jurisdiction. 36 CM/L-6819184 IS : 7098 (Pt.1) AS 9100 ISO 45001 ISO 9001 ISO 14001
Made with FlippingBook
RkJQdWJsaXNoZXIy NDgyMjA=