BS 5467 Power cable

Wires & Cables Area Cond.Min. No.of Wires Thickness of EBXL / XLPE Insulation (Nom.) Approx Overall diameter Approx.Net Wt.of Cable Max.D.C Resistance at 20 deg.C Current Rating For EBXL -XLPE Cables (125°C) Direct in Ground Current Rating For Chemically Cured XLPE Cables (90°C) Short Circuit Rating for 1sec Direct in Ground Thickness of PVC Inner Sheath Dimension of Arm Wire Thickness of Outer Sheath Area Cond.Min. No.of Wires Thickness of EBXL / XLPE Insulation (Nom.) Approx Overall diameter Approx.Net Wt.of Cable Max.D.C Re istance at 20 deg.C i l irect in round In Duct In Air u rent Rating For Che ica ly Cured L Cables (90° ) Short Circuit Rating for 1 sec i t i In Duct In Air Sq.mm Nos mm mm Kg/Km Ω/KM Dimension of Arm st ips Thickness of Outer Sheath mm mm Cu Cu Cu Cu Cu Cu Cu Product Construction ü Conductor : Annealed Plain copper conductor complying with BS 6360 ü Insulation : Electron Beam Cross Linked Polyethylene 120°C ü Armour : GI Strips ü Jacket : PVC Complying with BS 6746 Siechem 2 Core APC Conductor EBXL - XLPE 120°C Insulated GI Strips Armoured PVC Sheathed 600/1000 V Power cable as per BS 5467 Application Features Technical Data ü Operating Temperature : -15°C to +120°C High Insulation resistance at elevated temperature ü Short Circuit Temperature : 280°C ü Bending radius (min) : 12 x Cable dia ü Rated Voltage :600/1000 V ü Test Voltage : 3.5 kV for 5 mins. ü Specification : BS 5467 Part Number 749E3002 749E3202 749E3402 749E3702 749E3802 749E4102 749E4202 749E4402 749E4602 749E4802 749E4902 25 35 50 70 95 120 150 185 240 300 400 7 7 19 19 19 37 37 37 61 61 61 0.9 0.9 1.0 1.1 1.1 1.2 1.4 1.6 1.7 1.8 2.0 1.6 1.7 1.8 1.9 2 2.1 2.2 2.4 2.5 2.5 2.5 28.7 32.6 37.3 42.5 48.0 52.8 58.4 64.8 72.1 79.4 89.7 1274 1623 2068 2642 3341 4015 4813 5830 7148 8620 10895 3.6 5.0 7.1 10.0 13.6 17.1 21.4 26.4 34.3 42.9 57.1 0.727 0.524 0.387 0.268 0.193 0.153 0.124 0.9991 0.0754 0.0601 0.0470 198 234 273 343 408 451 511 576 660 745 803 178 211 255 309 368 417 472 530 606 683 770 173 203 281 317 387 432 495 576 680 770 872 152 180 210 264 314 347 393 443 508 573 618 137 162 196 238 283 321 363 408 466 525 592 133 156 216 244 298 332 381 443 523 592 671 0.8 X 4 0.8 X 4 0.8 X 4 0.8 X 4 0.8 X 4 0.8 X 4 0.8 X 4 0.8 X 4 0.8 X 4 0.8 X 4 0.8 X 4 ü Transmission and distribution of Power Industrial units ü Commercial and residential places ü Indoor and outdoor uses ü Cable ducts, cable trays conduits Direct burial and underground burial where mechanical damage risk for cables. ü Electron Beam Cross Linked. ü Enhanced Mechanical, Electrical, Thermal & Weathering properties. ü Soldering iron resistant ü Resistance to corona effect. ü Easy jointing & termination ü Better resistance to most chemicals & acids ü Low direct electric losses. ü High current carrying capacity. Siechem 2 CoreAPC Conductor EBXL - XLPE 120°C Insulated GI StripsArmoured PVC Sheathed 600/1000 V Power cable as per BS 5467 Cable conforming to IEC 60502 & VDE-0271 also available according to customer requirement. 749E Catalogue No www.siechem.com All information given are in good faith.Siechem's liability is only to replace the defective portion of cables provided the same is mutually established as manufacturing defects within the guarantee period as agreed in writing and Siechem shall not be liable for any compensation or damages. Siechem reserves the right to revise any of the above specifications without prior intimation. Subject to Chennai Jurisdiction. 35 CM/L-6819184 IS : 7098 (Pt.1) AS 9100 ISO 45001 ISO 9001 ISO 14001

RkJQdWJsaXNoZXIy NDgyMjA=