BS 5467 Power cable

Wires & Cables Area Cond.Min. No.of Wires Thickness of EBXL / XLPE Insulation (Nom.) Approx Overall diameter Approx.Net Wt.of Cable Max.D.C Resistance at 20 deg.C Current Rating For EBXL -XLPE Cables (125°C) Direct in Ground In Duct In Air Current Rating For Chemically Cured XLPE Cables (90°C) Short Circuit Rating for 1 sec Direct in Ground In Duct In Air Sq.mm Nos mm mm Kg/Km Ω/KM Dimension of Arm Wire Thickness of Outer Sheath mm mm Cu Cu Cu Cu Cu Cu Cu Product Construction ü Conductor : Annealed Plain copper conductor complying with BS 6360 ü Insulation : Electron Beam Cross Linked Polyethylene 120°C ü Armour : GI wire ü Jacket : PVC Complying with BS 6746 Siechem 2 Core Round APC Conductor EBXL - XLPE 120°C Insulated GI wire Armoured PVC Sheathed 600/1000 V Power cable as per BS 5467 Application Features Technical Data ü Operating Temperature : -15°C to +120°C High Insulation resistance at elevated temperature ü Short Circuit Temperature : 280°C ü Bending radius (min) : 12 x Cable dia ü Rated Voltage :600/1000 V ü Test Voltage : 3.5 kV for 5 mins. ü Specification : BS 5467 Part Number 1.5 2.5 4 6 10 16 25 35 1 1 1 1 7 7 7 7 0.6 0.7 0.7 0.7 0.7 0.7 0.9 0.9 0.9 0.9 0.9 0.9 0.9 1.2 51.2 51.6 1.3 1.4 1.4 1.4 1.5 1.5 1.6 1.7 13.8 15.2 16.3 17.4 19.5 22.3 25.9 29.5 341 413 483 565 724 1033 1396 1897 12.1 7.41 4.61 3.08 1.83 1.15 0.727 0.524 0.21 0.36 0.57 0.86 1.4 2.3 3.6 5.0 43 56 73 92 120 151 198 234 39 51 65 83 108 135 178 211 38 51 65 79 104 134 173 203 33 43 56 71 92 116 152 180 30 39 50 64 83 104 137 162 29 39 50 61 80 103 133 156 743ER1302 743ER1602 743ER1902 743ER2302 744ER2702 744ER2802 744ER3002 744ER3202 ü Transmission and distribution of Power Industrial units ü Commercial and residential places ü Indoor and outdoor uses ü Cable ducts, cable trays conduits Direct burial and underground burial where mechanical damage risk for cables. ü Electron Beam Cross Linked. ü Enhanced Mechanical, Electrical, Thermal & Weathering properties. ü Soldering iron resistant ü Resistance to corona effect. ü Easy jointing & termination ü Better resistance to most chemicals & acids ü Low direct electric losses. ü High current carrying capacity. Siechem 2 Core RoundAPC Conductor EBXL - XLPE 120°C Insulated GI wireArmoured PVC Sheathed 600/1000 V Power cable as per BS 5467 Cable conforming to IEC 60502 & VDE-0271 also available according to customer requirement. 743ER 744ER Catalogue No www.siechem.com All information given are in good faith.Siechem's liability is only to replace the defective portion of cables provided the same is mutually established as manufacturing defects within the guarantee period as agreed in writing and Siechem shall not be liable for any compensation or damages. Siechem reserves the right to revise any of the above specifications without prior intimation. Subject to Chennai Jurisdiction. 34 CM/L-6819184 IS : 7098 (Pt.1) AS 9100 ISO 45001 ISO 9001 ISO 14001

RkJQdWJsaXNoZXIy NDgyMjA=