BS 5467 Power cable

Wires & Cables Area Cond.Min. No.of Wires Thickness of EBXL / XLPE Insulation (Nom.) Thickness of Outer Sheath Approx Overall diameter Approx.Net Wt.of Cable Max.D.C Resistance at 20 deg.C Current Rating For EBXL -XLPE Cables (125°C) Direct in Ground In Duct In Air Current Rating For Chemically Cured XLPE Cables (90°C) Short Circuit Rating for 1 sec Direct in Ground In Duct In Air Sq.mm Nos mm mm mm Kg/Km Ω/KM Cu Cu Cu Cu Cu Cu Cu Product Construction ü Conductor : Annealed Plain copper conductor complying with BS 6360 ü Insulation : Electron Beam Cross Linked Polyethylene 120°C ü Jacket : PVC Complying with BS 6746 Siechem 4 Core APC Conductor EBXL - XLPE 120°C Insulated PVC Sheathed 600/1000 V (UA) Power cable as per BS 5467 Application Features Technical Data ü Operating Temperature : -15°C to + 120°C High Insulation resistance at elevated temperature ü Short Circuit Temperature : 280°C ü Bending radius (min) : 12 x Cable dia ü Rated Voltage :600/1000 V ü Test Voltage : 3.5 kV for 5 mins. ü Specification : BS 5467 Part Number 16 25 35 50 70 95 120 150 185 240 300 400 7 7 7 7 19 19 19 19 37 37 37 61 0.7 0.9 0.9 1.0 1.1 1.1 1.2 1.4 1.6 1.7 1.8 2.0 1.8 2.0 2.0 2.0 2.2 2.2 2.4 2.6 2.8 3.0 3.2 3.4 19.1 22.9 25.2 28.5 33.1 36.6 40.5 45.3 50.5 56.4 62.0 70.8 816 1222 1612 2204 3032 3972 4965 6198 7619 9767 12076 15945 126 159 190 224 274 329 373 417 469 541 603 677 1.15 0.727 0.524 0.387 0.268 0.193 0.153 0.124 0.0991 0.0754 0.0601 0.0470 113 143 170 202 247 296 335 376 423 486 543 610 117 143 182 211 257 312 359 413 476 552 624 710 2.3 3.6 5.0 7.1 10.0 13.6 17.1 21.4 26.4 34.3 42.9 57.1 97 122 146 172 211 253 287 321 361 416 464 521 87 110 131 155 190 228 258 289 325 374 418 469 90 110 140 162 198 240 276 318 366 426 480 546 748E2804 748E3004 748E3204 748E3404 748E3704 748E3804 748E4104 748E4204 748E4404 748E4604 748E4804 748E4904 ü Transmission and distribution of Power Industrial units ü Commercial and residential places ü Indoor and outdoor uses ü Cable ducts, cable trays conduits Direct burial and underground burial where mechanical damage risk for cables. ü Electron Beam Cross Linked. ü Enhanced Mechanical, Electrical, Thermal & Weathering properties. ü Soldering iron resistant ü Resistance to corona effect. ü Easy jointing & termination ü Better resistance to most chemicals & acids ü Low direct electric losses. ü High current carrying capacity. Siechem 4 CoreAPC Conductor EBXL - XLPE 120°C Insulated PVC Sheathed 600/1000 V (UA) Power cable as per BS 5467 Cable conforming to IEC 60502 & VDE-0271 also available according to customer requirement. 748E Catalogue No www.siechem.com All information given are in good faith.Siechem's liability is only to replace the defective portion of cables provided the same is mutually established as manufacturing defects within the guarantee period as agreed in writing and Siechem shall not be liable for any compensation or damages. Siechem reserves the right to revise any of the above specifications without prior intimation. Subject to Chennai Jurisdiction. 32 CM/L-6819184 IS : 7098 (Pt.1) AS 9100 ISO 45001 ISO 9001 ISO 14001

RkJQdWJsaXNoZXIy NDgyMjA=