BS 5467 Power cable

Area Cond.Min. No.of Wires Thickness of EBXL / XLPE Insulation (Nom.) Thickness of Outer Sheath Approx Overall diameter Approx.Net Wt.of Cable Max.D.C Resistance at 20 deg.C Current Rating For EBXL -XLPE Cables (125°C) Direct in Ground In Duct In Air Current Rating For Chemically Cured XLPE Cables (90°C) Short Circuit Rating for 1 sec Direct in Ground In Duct In Air Sq.mm Nos mm mm mm Kg/Km Ω/KM Cu Cu Cu Cu Cu Cu Cu Product Construction Wires & Cables ü Conductor : Annealed Plain copper conductor complying with BS 6360 ü Insulation : Electron Beam Cross Linked Polyethylene 120°C ü Jacket : PVC Complying with BS 6746 Siechem 3 Core Round APC Conductor EBXL - XLPE 120°C Insulated PVC Sheathed 600/1000 V (UA) Power cable as per BS 5467 Application Features Technical Data ü Operating Temperature : -15°C to +120°C High Insulation resistance at elevated temperature ü Short Circuit Temperature : 280°C ü Bending radius (min) : 12 x Cable dia ü Rated Voltage :600/1000 V ü Test Voltage : 3.5 kV for 5 mins. ü Specification : BS 5467 i l Part Number 1.5 2.5 4 6 10 16 25 1 1 1 1 7 7 7 0.6 0.7 0.7 0.7 0.7 0.7 0.9 1.8 1.8 1.8 1.8 1.8 1.8 1.8 11.5 12.8 14.0 15.2 17.2 19.7 23.4 172 226 289 367 516 734 1076 12.1 7.41 4.61 3.08 1.83 1.15 0.727 33 44 57 72 95 126 159 30 40 52 65 86 113 143 29 39 52 65 82 117 143 25 34 44 55 73 97 122 23 31 40 50 66 87 110 0.21 0.36 0.57 0.86 1.4 2.3 3.6 22 30 40 51 63 90 110 741E1303 741E1603 741E1903 741E2303 742E2703 742E2803 742E3003 ü Transmission and distribution of Power Industrial units ü Commercial and residential places ü Indoor and outdoor uses ü Cable ducts, cable trays conduits Direct burial and underground burial where mechanical damage risk for cables. ü Electron Beam Cross Linked. ü Enhanced Mechanical, Electrical, Thermal & Weathering properties. ü Soldering iron resistant ü Resistance to corona effect. ü Easy jointing & termination ü Better resistance to most chemicals & acids ü Low direct electric losses. ü High current carrying capacity. Cable conforming to IEC 60502 & VDE-0271 also available according to customer requirement. 741E 742E Catalogue No www.siechem.com All information given are in good faith.Siechem's liability is only to replace the defective portion of cables provided the same is mutually established as manufacturing defects within the guarantee period as agreed in writing and Siechem shall not be liable for any compensation or damages. Siechem reserves the right to revise any of the above specifications without prior intimation. Subject to Chennai Jurisdiction. 28 Siechem3CoreRoundAPCConductorEBXL -XLPE120°C InsulatedPVCSheathed600/1000V (UA)Power cable asperBS 5467 CM/L-6819184 IS : 7098 (Pt.1) AS 9100 ISO 45001 ISO 9001 ISO 14001

RkJQdWJsaXNoZXIy NDgyMjA=