BS 5467 Power cable
Wires & Cables Product Construction Technical Data Area Cond.Min. No.of Wires Thickness of EBXL / XLPE Insulation (Nom.) Thickness of Outer Sheath Approx Overall diameter Approx.Net Wt.of Cable Max.D.C Resistance at 20 deg.C Current Rating For EBXL -XLPE Cables (125°C) Direct in Ground In Duct In Air Current Rating For Chemically Cured XLPE Cables (90°C) Short Circuit Rating for 1 sec Direct in Ground In Duct In Air Sq.mm Nos mm mm mm Kg/Km Ω/KM Cu Cu Cu Cu Cu Cu Cu ü Conductor : Annealed Plain copper conductor complying with BS 6360 ü Insulation : Electron Beam Cross Linked Polyethylene 120°C ü Jacket : PVC Complying with BS 6746 Siechem 2 Core APC Conductor EBXL - XLPE 120°C Insulated PVC Sheathed 600/1000 V (UA) Power cable as per BS 5467 Part Number 742E3002 742E3202 742E3402 742E3702 742E3802 742E4102 742E4202 742E4402 742E4602 742E4802 742E4902 Application Features ü Transmission and distribution of Power Industrial units ü Commercial and residential places ü Indoor and outdoor uses ü Cable ducts, cable trays conduits Direct burial and underground burial where mechanical damage risk for cables. ü Operating Temperature : -15°C to +120°C High Insulation resistance at elevated temperature ü Short Circuit Temperature : 280°C ü Bending radius (min) : 12 x Cable dia ü Rated Voltage :600/1000 V ü Test Voltage : 3.5 kV for 5 mins. ü Specification : BS 5467 3.6 5.0 7.1 10.0 13.6 17.1 21.4 26.4 34.3 42.9 57.1 0.727 0.524 0.387 0.268 0.193 0.153 0.124 0.9991 0.0754 0.0601 0.0470 198 234 273 343 408 451 511 576 660 745 803 178 211 255 309 368 417 472 530 606 683 770 173 203 281 317 387 432 495 576 680 770 872 152 180 210 264 314 347 393 443 508 573 618 137 162 196 238 283 321 363 408 466 525 592 133 156 216 244 298 332 381 443 523 592 671 25 35 50 70 95 120 150 185 240 300 400 7 7 7 19 19 70 70 37 37 37 61 0.9 0.9 1.0 1.1 1.1 1.2 1.4 1.6 1.7 1.8 2.0 1.8 1.8 1.8 1.8 1.9 2 2.2 2.3 2.5 2.6 2.9 26.5 29.8 34.3 39.3 44.4 49.2 55.0 60.8 68.3 75.4 86.3 780 1002 1336 1767 2296 2839 3527 4294 5464 6697 8811 Siechem 2 CoreAPC Conductor EBXL - XLPE 120°C Insulated PVC Sheathed 600/1000V (UA) Power cable as per BS 5467 ü Electron Beam Cross Linked. ü Enhanced Mechanical, Electrical, Thermal & Weathering properties. ü Soldering iron resistant ü Resistance to corona effect. ü Easy jointing & termination ü Better resistance to most chemicals & acids ü Low direct electric losses. ü High current carrying capacity. Cable conforming to IEC 60502 & VDE-0271 also available according to customer requirement. 742E Catalogue No www.siechem.com All information given are in good faith.Siechem's liability is only to replace the defective portion of cables provided the same is mutually established as manufacturing defects within the guarantee period as agreed in writing and Siechem shall not be liable for any compensation or damages. Siechem reserves the right to revise any of the above specifications without prior intimation. Subject to Chennai Jurisdiction. 27 CM/L-6819184 IS : 7098 (Pt.1) AS 9100 ISO 45001 ISO 9001 ISO 14001
Made with FlippingBook
RkJQdWJsaXNoZXIy NDgyMjA=